Configuring the Virtual Connect domain using the CLI 160
The login should succeed after the Virtual Connect Manager restarts on the backup Virtual Connect Ethernet
module. Allow up to 5 minutes, depending on the enclosure configuration.
If the command line option -failover is not included in the reset vcm command or a backup Virtual
Connect Ethernet module is not available, the command line displays the following message:
SUCCESS: The Virtual Connect Manager is being reset. Please wait...
You are logged out of the session after approximately 1 minute. If you attempt to log in to the module again,
you might receive the following error message:
Unable to communicate with the Virtual Connect Manager. Please retry again
later.
The login should succeed after the Virtual Connect Manager restarts. Allow up to 5 minutes, depending on
the enclosure configuration.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem