Server-port-map-range – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 84

Command line 84
Item
Description
set server-port-map Modify an existing server port network mapping. This command cannot be used if
the network is associated with a shared uplink set.
Syntax
set server-port-map
[VLanID=
Parameters
ConnectionID
(required)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
Network (required) The name of a valid Ethernet network on which the mapping exists
Properties
VLanID (optional)
The new VLAN ID to be used for server port network mapping. Valid values include
1 to 4094.
Untagged (optional) Enables or disables the network to handle untagged packets. Only one network in
an Ethernet network connection can handle untagged packets. The default value is
"false". If a shared uplink set is used, the untagged network is the same as the native
network, if present, but any network can also be configured to handle untagged
packets. When changing a network untagged option from "true" to "false", you
must specify a VLanID if the global option SharedServerVLanId is set to "false".
Examples
->set server-port-map MyProfile:1 Network1 VLanId=100
Modifies the VLAN ID of an existing server port network mapping
->set server-port-map MyProfile:1 Network1 Untagged=true
Modifies the existing server port network mapping to handle untagged packets
Item
Description
show server-port-map Display a server port network mapping.
Syntax
show server-port-map [
Parameter
ConnectionID
(optional)
The ID of an existing Ethernet connection associated with a profile and a server
port. The format of the ConnectionID is
Examples
->show server-port-map
Displays a summary of all the server port mappings
->show server-port-map MyProfile:1
Displays the server port mapping for a profile
->show server-port-map *
Displays detailed output of all server port mappings
server-port-map-range
Manage ranges of shared server downlink port mapping configurations.
Supported actions: add, help, remove
Item
Description
add server-port-
map-range
Add a new server port network mapping range, and allow server ports to be shared
among multiple VC Ethernet networks.
Syntax
add server-port-map-range Set Name> VLANIDs= [MatchUplinkSet=
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem