Port-monitor – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 69

Command line 69
Item
Description
Nags (optional)
The network access groups to which the networks belong, separated by
commas. Do not use spaces unless they are enclosed in quotation marks.
If nags is not specified, the network access groups are not changed.
SmartLink (optional)
Enables or disables the SmartLink capability for the networks. Valid values
include "Enabled" and "Disabled".
Labels (optional)
Labels assigned to these networks. Labels are used in the GUI to help with
management of large numbers of networks. Labels can be assigned in the
CLI, but are only used in the GUI. A maximum of 16 labels can be
assigned.
Color (optional)
Color assigned to these networks. Color is used in the GUI to help with
management of large numbers of networks. A color can be assigned in
the CLI, but is only used in the GUI. Allowed colors are red, green, blue,
purple, or orange.
Example
->set network-range UplinkSet=Alpha
VLANIDs=1-10,21-30 SmartLink=Enabled
Changes the SmartLink setting for multiple networks
port-monitor
Manage port monitor configuration.
Supported actions: help, add, remove, set, show
Item
Description
add port monitor
Add a new network analyzer port and other ports to be monitored.
Syntax
add port-monitor [AnalyzerPort=
[Speed=
[Duplex=
[Direction=
Properties
AnalyzerPort
(optional)
The uplink port that is used for monitoring network traffic. Only one port can be
configured as the analyzer port. After a port is allocated to port monitoring, it is not
available for use in VC networks and shared uplink sets. The format of the network
analyzer port is
If the EnclosureID is not specified, the default enclosure is the local enclosure where
the domain resides.
Speed (optional)
The port speed for the network analyzer port. Valid values include "Auto",
"10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". The default value is "Auto".
If there is no connector present on the analyzer port, only "Auto" and "Disabled"
can be configured as the port speed. Speed restrictions apply.
Duplex (optional)
The duplex mode of the network analyzer port. Valid values include "Auto", "Half",
and "Full". The default value is "Auto".
MonitorPort
(optional)
The server port to be monitored. The format of the monitored port is
specified, the default enclosure is the local enclosure.
The ID for the monitor port can be referenced from the ID column in the output of the
show server-port command.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem