HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 38

Command line 38
Item
Description
Adds a new FC SAN connection and uses the next available fabric
->add fc-connection MyNewProfile
AddressType=Factory-Default
Adds a new FC SAN connection and uses factory-default addresses
->add fc-connection MyNewProfile AddressType=User-Defined
PortWWN=50:06:0B:00:00:C2:62:00
NodeWWN=50:06:0B:00:00:c2:62:01
Adds a new FC SAN connection and provides user-defined WWN addresses
Item
Description
remove fc-connection
Remove the last FC connection from an existing server profile.
Syntax
remove fc-connection
Parameter
ProfileName (required) The name of an existing profile from which the last FC connection is being
removed
Example
->remove fc-connection MyProfile
Removes an FC connection from a profile
Item
Description
set fc-connection
Modify an existing FC SAN connection.
Syntax
set fc-connection
[Fabric=
[Speed=
[BootPriority=
[BootLun=
Parameters
ProfileName (required) The name of the server profile that contains the connection being modified
Port (required)
The port number of the connection being modified
Properties
Fabric (optional)
The name of the FC SAN fabric to associate with the connection. The fabric
being specified should be associated with the same bay as the FC connection.
A blank string makes the FC connection unassigned.
Speed (optional)
The port speed of the FC SAN connection. Valid values include "Auto", "8Gb",
"4Gb", "2Gb", "1Gb", and "Disabled".
Speed restrictions:
For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module,
supported speed values include "Auto","1Gb","2Gb", "4Gb", and
"Disabled". If the value is set to 8Gb, the speed is auto-negotiated by Virtual
Connect.
BootPriority
(optional)
Controls whether the FC HBA port is enabled for SAN boot and affects the BIOS
boot order. Valid values include "BIOS", "Primary", "Secondary", and
"Disabled".
BootPort
(Required if the Boot Priority is
either Primary or
Secondary optional)
The target WWPN of the controller interface on the Fibre Channel storage
target. The port name is a 64-bit identifier in the format
NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number.
BootLun
(Required if the Boot Priority is
The LUN of the volume used for SAN boot. Valid values include an integer from
0 to 255 or 16 hex digits (HP-UX only).
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem