Command line 103
Item
Description
Parameters
PortID (required) The ID of the port to remove from a network. The port ID must be in the format
If EnclosureID is not specified, it defaults to the local enclosure.
Network
(optional)
The name of the network from which the port is removed
UplinkSet
(optional)
The name of the shared uplink set from which the port is removed
Examples
->remove uplinkport enc0:1:2 Network=MyNetwork
Removes a specific uplink port (Bay 1, Port 2) from a network named MyNetwork
->remove uplinkport * Network=BlueNetwork
Removes all uplink ports from a network named BlueNetwork
->remove uplinkport enc0:2:3 UplinkSet=SharedUplinkSet1
Removes a specific uplink port (Bay 2, Port 3) from a shared uplink set
Item
Description
set uplinkport
Modify an uplink port that exists as a member of a network or shared uplink port set.
Syntax
set uplinkport
UplinkSet= 10Gb|Disabled>] [Role= Parameter PortID (required) The ID of the port to modify. The specified port must already be added to a network or shared uplink set. The port ID is in the format Properties Network (required) The name of the network to which the port belongs if the shared uplink set name is not specified UplinkSet (required) The name of the shared uplink set to which the port belongs if the network name is not specified Speed (optional) Specifies the port speed for the port. Valid values include "Auto", "10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". If no connector is present on the uplink port, only "Auto" and "Disabled" can be Role (optional) The role played by the port if the connection mode of the network or shared uplink set is selected as "Failover". Valid values are "Primary" and "Secondary". The default value is "Primary". Examples ->set uplinkport enc0:1:2 Network=MyNetwork Speed=1Gb Changes the port speed of a network port ->set uplinkport enc0:2:1 Network=MyNetwork Speed=Disabled Disables a specific port that belongs to a network ->set uplinkport enc0:2:4 UplinkSet=MyUplinkSet Speed=Disabled Disables a specific port that belongs to a shared uplink set ->set uplinkport enc0:2:4 Network=MyNetwork Role=Secondary Modifies the role of the network uplink port with the connection mode on the network or the shared uplink set as "Failover" to take the Secondary port role Item Description show uplinkport Display all Ethernet module uplink ports known to the domain. If the port is a member of a network or a shared uplink set, it appears. If the port is unlinked and no
configured as the speed. Speed restrictions apply.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem