HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 97

Command line 97
Item
Description
show statistics-
throughput
Display throughput information for the specified physical port, FlexNIC, and the
aggregated throughput information for the specified LAG.
Syntax
show statistics-throughput
[LAGID=
Parameters
PortID (optional) The port ID of the port/subport for which to display throughput information. PortID is
composed of
throughput collection must be enabled for the domain by issuing the set
statistics-throughput command. A column that contains an "R" indicates that
the statistics were reset by the user during that time period, therefore the throughput is
not available for that time period.
config (required
if PortID is not
specified)
Displays the current configuration of throughput statistics
Property
LAGID (optional) The LAG ID on which to display throughput information. The LAG ID must be in the
format
format lagNN, where NN is the LAG number.
A listing of the possible uplink port IDs can be obtained by using the show
uplinkport command.
Examples
->show statistics-throughput enc0:1:X1
Displays the port throughput statistics for port X1 of the module in bay1 of enclosure
enc0
->show statistics-throughput enc0:1:d1:v1
Displays the subport throughput statistics for subport v1 of port d1 from the module in
bay1 of enclosure enc0
->show statistics-throughput config
Displays the current configuration of the throughput statistics
->show statistics-throughput LAGID=enc0:1:lag25
Displays the aggregated throughput statistics based on the LAGID 25 for the module in
bay1 of enclosure enc0
Item
Description
set statistics-
throughput
Enable or disable the port throughput statistics and set the sample rate.
Syntax
set statistics-throughput
[SampleRate=<1m|2m|3m|4m|5m|1h>]>
Parameters
Enabled
(optional)
Enables or disables port throughput statistics. Valid values include "true" and "false".
SampleRate
(optional)
Configures the sample rate for statistics collection. Valid values include:
•
Use SampleRate=1m for 1 minute samples, collecting up to 5 hours of samples.
•
Use SampleRate=2m for 2 minutes samples, collecting up to 10 hours of samples.
•
Use SampleRate=3m for 3 minutes samples, collecting up to 15 hours of samples.
•
Use SampleRate=4m for 4 minutes samples, collecting up to 20 hours of samples.
•
Use SampleRate=5m for 5 minutes samples, collecting up to 25 hours of samples.
•
Use SampleRate=1h for 60 minutes samples, collecting up to 12.5 days of
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem