Item
Description
Setting the value to "true" restricts the server network connections to be selected
from a single shared uplink, and the VLAN ID cannot be modified.
Setting the value to "false" enables you to select any VC Ethernet network for the
server Ethernet connections, and VLAN ID mappings can be modified to ensure
uniqueness.
PrefSpeedType
(optional)
The default connection speed for any Ethernet connection using multiple
networks. Valid values include "Auto" and "Custom". "Custom" enables you to
configure the preferred speed. The default value is "Auto".
PrefSpeed (required if
PrefSpeedType is
Custom)
The default connection speed for any Ethernet connection using multiple
networks. Valid values range from 100Mb to 10Gb in 100Mb increments.
MaxSpeedType
(optional)
The maximum connection speed for any Ethernet connection using multiple
networks. Valid values include "UnRestricted" and "Custom". "Custom" enables
you to configure the preferred speed. The default value is "Unrestricted".
MaxSpeed (required if
MaxSpeedType is
Custom)
The maximum connection speed for any Ethernet connection using multiple
networks. Valid values range from 100Mb to 10Gb in 100Mb increments.
VlanCapacity
(optional)
The VLAN capacity mode. Valid values include 'Legacy' and 'Expanded'.
'Legacy' mode allows up to 320 VLANs per module and 28 VLANs per server
connection. All VC-Enet modules are supported. This is the default setting.
'Expanded' mode allows up to 1000 VLANs per domain and 162 VLANs per
physical server port.
Examples
->set enet-vlan SharedServerVLanId=true
Enables SharedServerVLanId
->set enet-vlan PrefSpeedType=Custom PrefSpeed=500
MaxSpeedType=Custom MaxSpeed=2500
Sets the preferred connection speed for all connections using multiple networks to
500Mb, and the maximum connection speed to 2.5Gb
->set enet-vlan VlanCapacity=Expanded
Sets the VLAN capacity mode to Expanded to allow for larger network
configurations
Item
Description
show enet-vlan
Display general Ethernet VLAN configuration settings.
Syntax
show enet-vlan
Example
->show enet-vlan
Displays Ethernet VLAN configuration settings
external-manager
Manage external manager settings and information.
Supported actions: help, remove, set, show
Item
Description
remove
external-manager
Remove an existing external manager (VCEM) and regain local management
profile control of the domain.
When releasing the profile control, you must specify values for each MacType,
WwnType, and ServerIdType.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem