Fcoe-connection – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 39

Command line 39
Item
Description
either Primary or
Secondary optional)
Examples
->set fc-connection MyProfile 1 Fabric=SAN_5
Changes the fabric of an FC SAN fabric connection
->set fc-connection RedProfile 2 Fabric=""
Sets an FC SAN fabric connection to "Unassigned"
->set fc-connection BlueProfile 1 Fabric=SAN_7
Changes the FC SAN fabric of an FC SAN connection
->set fc-connection BlueProfile 1 Speed=4Gb
Changes the port speed of an FC SAN connection
->set fc-connection BlueProfile 1 BootPriority=Primary
BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
Changes the SAN boot priority and sets additional boot parameters
Item
Description
show fc-connection
Display the FC SAN connections associated with the server profiles.
Syntax
show fc-connection [
Parameter
ConnectionID
(optional)
The ID of an existing FC SAN connection. The ID format is
Use
display all FC SAN connections in the domain.
Examples
->show fc-connection
Displays all FC SAN connections in the domain
->show fc-connection Profile1:*
Displays all FC SAN connections of a profile named Profile1
->show fc-connection Profile1:1
Displays a specific FC SAN connection of a profile named Profile1
fcoe-connection
Manage FCoE connections.
Supported actions: add, help, remove, set, show
Item
Description
add fcoe-connection
Add a new FCoE connection to an existing server profile.
For more information, see "General requirements for adding FC or FCoE
)."
Syntax
add fcoe-connection
[SpeedType=<1Gb|2Gb|4Gb|8Gb|Custom|Disabled>]
[CustomSpeed=<100Mb-10Gb>]
[WWNAddressType=
[PortWWN=
[MACAddressType=
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem