Adding ethernet network connections to a profile, Adding iscsi connections to a profile, Adding fc fabric connections to a server profile – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 150: Adding fcoe connections to a profile

Configuring the Virtual Connect domain using the CLI 150
A server profile can be assigned and defined for each device bay so that the server blade can be powered
on and connected to a deployment network. These profiles can then later be modified or replaced by another
server profile.
A server profile can also be assigned to an empty bay to enable deployment at a later date.
Adding Ethernet network connections to a profile
To add a new Ethernet network connection to an existing server profile, use the add enet-connection
command:
>add enet-connection MyProfile network=MyNetwork pxe=enabled
To add a multiple network Ethernet connection on a server port, use the following commands:
>add enet-connection MyProfile pxe=enabled
>add server-port-map MyProfile:1 MyNetwork VlanID=100
>add server-port-map-range MyProfile:1 VLanIds=151-170,215
If the domain setting for SharedServerVlanID is set to true, then the VlanID property cannot be
modified. Instead, the name of the shared uplink set with which the network is associated is required.
>add server-port-map MyProfile:1 MyNetwork Uplinkset=MyUplinkset
Adding iSCSI connections to a profile
To add a new iSCSI connection to an existing server profile, use the add iscsi-connection command:
>add iscsi-connection MyProfile network=MyNetwork speedType=custom
speed=2000
To configure the boot parameters for the iSCSI connection, use the set iscsi-boot-param command as
follows:
>set iscsi-boot-param MyProfile1:1 BootOrder=Primary Lun=100
InitiatorName="iqn.2009-09.com.someorg.iSCSI-Initiator"
InitiatorIp=192.128.3.1 Mask=255.255.0.0
TargetName="iqn.2009-09.com.someorg.iSCSI-Target" TargetIp=192.128.3.2
TargetPort=40000 Authentication=CHAP Username=SomeUserName
Secret=SomePassword123
Adding FC fabric connections to a server profile
To add a new FC SAN connection to an existing server profile, use the add fc-connection command:
>add fc-connection MyProfile fabric=SAN_5
For more information, see "General requirements for adding FC or FCoE connections (on page
)."
Adding FCoE connections to a profile
To add a new FCoE connection to an existing server profile, use the add fcoe-connection command:
>add fcoe-connection MyNewProfile Fabric=SAN_1 SpeedType=Custom
CustomSpeed=5000
To configure the boot parameters for the FCoE connection, use the set fcoe-connection command:
>set fcoe-connection MyNewProfile:1 BootPriority=Primary
BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
For more information, see "General requirements for adding FC or FCoE connections (on page
)."
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem