beautypg.com

View log as text, View log as a graphic, Operating procedures – Dwyer Series PUF User Manual

Page 31

background image

3: Operating Procedures

27

View log as text

View log as a graphic

8.

The

VIEW LOG AS TEXT screen displays the

log events in date-stamped chronological order.

Note: Press key 5 to go to the top line of
logged data or key 6 to go to the bottom line.

9.

Press the

ENTER key to return to the REAL TIME

LOGGER screen. Then select Exit to return to
the

FLOW READING screen. Logging will

continue to take place in the background.

VIEW LOG AS TEXT

DD-MM-YY HH:MM:SS

Logging to memory

Log:Quickstart

Date Time Flow Totals

DD-MM-YY hh:mm:ss xxx.xx

DD-MM-YY hh:mm:ss xxx.xx

DD-MM-YY hh:mm:ss xxx.xx

DD-MM-YY hh:mm:ss xxx.xx

--------

DD-MM-YY hh:mm:ss xxx.xx L/m

Key Point: There can be only one set of logged data per site. If a new data log is started
on a site it will clear the existing data.

10. If you want to view the logging progress

graphically rather than as text, press the
Logger function key to get to the REAL TIME
LOGGER screen.

11. Select

Graph Y axis max and enter a value

equal to the expected maximum flow.

12. Select

View log as graph. This will open the

VIEW LOG AS GRAPH screen shown below.

13. You can select the data at any point in time by

scrolling along the time axis of the graph using
the

LEFT/RIGHT scroll keys (5 & 6). The data

values for the selected point are then shown to
the left of the graph. Keep the scroll key pressed
for the cursor to move automatically.

REAL TIME LOGGER

DD-MM-YY HH:MM:SS

4-20mA O/P is ON. Qxx.xx%

Unit : gal/min

Log name : Quickstart

Log data to : Memory

Logging interval : 10 seconds

Start date & time : dd-mm-yy hh:mm:ss

Stop date & time : dd-mm-yy hh:mm:ss

MM DD HH MM SS

Remaining time : mm dd hh mm ss

Sleep Mode : Off

Extended Intervals : Stop

Graph Y axis max. : 50

View log as text

View log as graph

START NOW

Set Auto start

Clear log

Exit

14. If you want to change the value of the Y axis to

improve the resolution of the graph press the
UP/DOWN scroll keys. The maximum values will
then increase/decrease as appropriate.

15. To exit the

VIEW LOG AS GRAPH screen and

return to the

REAL TIME LOGGER screen press

the

ENTER key.

VIEW LOG AS GRAPH

DD-MM-YY HH:MM:SS

Qxx.xx%

50.00

Log: Quickstart

Point: XXX/XXX

Value: xx.xx

dd-mm-yy hh:mm:ss

gal/min –50.00