Easicool™ precision air conditioning, Technical data, Te ch ni ca l o utd oo r – Airedale EasiCool 6kW 64kW User Manual
Page 190

EasiCool™
Precision Air Conditioning
CR50
CR65
CR80
CR105
Unit Data
(1)
Nominal Run Amps
A
6.04
6.04
9.06
9.06
Maximum Start Amps
A
15.4
15.4
23.1
23.1
Recommended Mains Fuse
A
10
10
16
16
Max Mains Cable Incoming
mm²
6
6
6
6
Mains Supply
220V / 2Ph / 60Hz
Fan - Per Fan
Quantity
2
2
3
3
Motor Size
kW
0.64
0.64
0.64
0.64
Full Load Amps
A
3.02
3.02
3.02
3.02
Locked Rotor Amps
A
7.7
7.7
7.7
7.7
OPTIONAL EXTRAS
Short Case Axial Fan - Per Fan
Quantity
2
2
3
3
Motor Size
kW
1.75
1.75
1.75
1.75
Full Load Amps
A
7.8
7.8
7.8
7.8
Locked Rotor Amps
A
19.5
19.5
19.5
19.5
EC Condenser Fan - Per Fan
Quantity
2
2
3
3
Motor Size
kW
0.73
0.73
0.73
0.73
Full Load Amps
A
3.3
3.3
3.3
3.3
(1)
Nominal data based on 35°C ambient and a 50°C mean condensing temperature and using standard fan.
Technical Data
Electrical Data -2
190
EasiCool Technical Manual 7535776 V1.1.0_04_2013