B.106 SYSTem:RAMP COMMAND
SYST:RAMP
Syntax:
Short Form: SYST:RAMP
Long Form: SYSTem:RAMP
Where
Description: Establishes the time for unit to change states in both positive and negative directions. See
SYST:RAMP:POS (PAR. B.108) and SYST:RAMP:NEG (PAR. B.110) to set different ramp times for
positive and negative directions.
Ramps work in all modes except power. The ramp consists of up to 4000 evenly spaced steps in times
from 4.5 microseconds to 2.50 milliseconds (max ramp time is 10 seconds). The ramp will either step
from one level to the other in 4.5 microsecond steps or will execute approximately 4000 steps at a time
required to meet the ramp duration. For example, a ramp of 1 millisecond consists of 222 steps (4.5
microseconds per step). A ramp of 100 milliseconds consists of 4000 steps (25 microseconds per
step). A ramp of 2 seconds consists of 4000 steps (0.5 milliseconds per step).
When using both ramps and transients at the same time, the following must be observed (see Figure
B-1 for timing, see PAR. B.100 to initiate a transient pulse.):
- Transient
- Transient pulse period
resistance and PAR. B.62 for voltage.
B.107 SYSTem:RAMP? QUERY
SYST:RAMP?
Syntax:
Short Form: SYST:RAMP?
Long Form: SYSTem:RAMP?
Returns:
Description: Indicates the larger of the positive and negative ramp times. For example, If SYST:RAMP:POS is
set to 2 and SYST:RAMP:NEG is set to 1.5, SYST:RAMP? returns 2.000.
B.108 SYSTem:RAMP:POSitive COMMAND
SYST:RAMP:POS
Syntax:
Short Form: SYST:RAMP:POS
Long Form: SYSTem:RAMP:POSitive
Where
Description: Establishes the time for unit to change states in positive direction. See SYST:RAMP command,
PAR. B.106 for ramp details. and restrictions.
B.109 SYSTem:RAMP:POSitive? QUERY
SYST:RAMP:POS?
Syntax:
Short Form: SYST:RAMP:POS?
Long Form: SYSTem:RAMP:POSitive?
Returns:
Description: Indicates the positive ramp time.
B.110 SYSTem:RAMP:NEGative COMMAND
SYST:RAMP:NEG
Syntax:
Short Form: SYST:RAMP:NEG
Where
Description: Establishes the time for unit to change states in negative direction. See SYST:RAMP command,
PAR. B.106 for details and restrictions.
B.111 SYSTem:RAMP:NEGative? QUERY
SYST:RAMP:NEG?
Syntax:
Short Form: SYST:RAMP:NEG?
Long Form: SYSTem:RAMP:NEGative?
Returns:
Description: Indicates the negative ramp time.