B.102 SYSTem:PFModule:DAMPing COMMAND

SYST:PFM:DAMP

Syntax:

Short Form: SYST:PFM:DAMP

Long Form: SYSTem:PFModule:DAMPing

Where = integer from 0 (minimum damping) to 5 (maximum damping)

Description: Establishes damping settings for Power FET Modules. Increased damping decreases the loop's

response time to transients. Factory default setting is 3.
Damping Settings: 0 - 1nF, 1 - 4.3nF, 2 - 11nF, 3 - 34nF, 4 - 101nF, 5 - 147.3nF. See PAR. 3.14 for
details.

B.103 SYSTem:PFModule:DAMPing? QUERY

SYST:PFM:DAMP?

Syntax:

Short Form: SYST:PFM:DAMP?

Long Form: SYSTem:PFModule:DAMPing?

Returns = integer from 0 (minimum damping) to 5 (maximum damping)

Description: Indicating damping settings for Power FET Modules. See PAR. 3.14 for details.

B.104 SYSTem:PFModule:LIST? QUERY

SYST:PFM:LIST?

Syntax:

Short Form: SYST:PFM:LIST?

Long Form: SYSTem:PFModule:LIST?

Description: List Power FET Modules within chassis (see below for example).

SYST:PFM:LIST?
KEPCO, EL 5K-200-600 01-18-2010,A999104,MCB #200 1.176 $ 2010/01/18 22:27:06 $

6 Power FET Modules Installed
Pos Serial

Revision

0 292

1.39

1 293
2 294

1.39

3 310

1.39

4 1200

1.39

5 296

NOTE: PFMs with no revision are using Firmware Revisions below 1.35.