B.50 [source:]resistance:transient command, B.51 [source:]resistance:transient? query, B.54 [source:]voltage:protection:over command – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 4.00 to 4.xx User Manual
Page 78: B.55 [source:]voltage:protection:over? query, B.50, Source, B.51, B.52, B.53, B.54

B-10
SERIES EL 071414
B.50
[SOURce:]RESistance:TRANsient COMMAND
RES:TRAN
Syntax:
Short Form: [SOUR:]RES:TRAN
Description: Configures a transient resistance pulse that is initiated by SYST:MODE:TRAN (see PAR. B.100).
See PAR. B.106 for details on using both Transient and Ramp commands at the same time. Figure B-
1 on page B-18 shows transient and ramp timing.
B.51
[SOURce:]RESistance:TRANsient? QUERY
RES:TRAN?
Syntax:
Short Form: [SOUR:]RES:TRAN?
Long Form: [SOURce:]RESistance:TRANsient?
Returns:
Description:Returns the transient resistance pulse parameters established by RES:TRAN (see PAR. B.50).
B.52
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude] COMMAND
VOLT
Syntax:
Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]
where:
Description: Establishes voltage setpoint. The voltage setpoint only affects the load when the load is in Voltage
mode of operation. Voltage setpoint is stored in non-volatile memory; value is restored upon power-up.
B.53
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? QUERY
VOLT?
Syntax:
Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]?
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]?
Returns:
Description: Indicates voltage setpoint.
B.54
[SOURce:]VOLTage:PROTection:OVER COMMAND
VOLT:PROT:OVER
Syntax:
Short Form: [SOUR:]VOLT:PROT:OVER
Long Form: [SOURce:]VOLTage:PROTection:OVER
where
Description: Sets overvoltage protection limit. Overvoltage protection setpoint is stored in non-volatile memory;
value is restored upon power-up.
B.55
[SOURce:]VOLTage:PROTection:OVER? QUERY
VOLT:PROT:OVER?
Syntax:
Short Form: [SOUR:]VOLT:PROT:OVER?
Long Form: [SOURce:]VOLTage:PROTection:OVER?
Returns
Description: Indicates overvoltage protection limit.
B.56
[SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel] COMMAND
VOLT:PROT:OVER:STAT 0
Syntax:
Short Form: [SOUR:]VOLT:PROT:OVER:STAT[:LEV] 0
Long Form: [SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel] 0
Description: Clears overvoltage protection error.