beautypg.com

B.50 [source:]resistance:transient command, B.51 [source:]resistance:transient? query, B.54 [source:]voltage:protection:over command – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 4.00 to 4.xx User Manual

Page 78: B.55 [source:]voltage:protection:over? query, B.50, Source, B.51, B.52, B.53, B.54

background image

B-10

SERIES EL 071414

B.50

[SOURce:]RESistance:TRANsient COMMAND

RES:TRAN

Syntax:

Short Form: [SOUR:]RES:TRAN ,

Description: Configures a transient resistance pulse that is initiated by SYST:MODE:TRAN (see PAR. B.100).

See PAR. B.106 for details on using both Transient and Ramp commands at the same time. Figure B-
1 on page B-18
shows transient and ramp timing.

B.51

[SOURce:]RESistance:TRANsient? QUERY

RES:TRAN?

Syntax:

Short Form: [SOUR:]RES:TRAN?
Long Form: [SOURce:]RESistance:TRANsient?
Returns: ,

Description:Returns the transient resistance pulse parameters established by RES:TRAN (see PAR. B.50).

B.52

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude] COMMAND

VOLT

Syntax:

Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]
where: = voltage setpoint

Description: Establishes voltage setpoint. The voltage setpoint only affects the load when the load is in Voltage

mode of operation. Voltage setpoint is stored in non-volatile memory; value is restored upon power-up.

B.53

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? QUERY

VOLT?

Syntax:

Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]?
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]?
Returns: = voltage setpoint

Description: Indicates voltage setpoint.

B.54

[SOURce:]VOLTage:PROTection:OVER COMMAND

VOLT:PROT:OVER

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER
Long Form: [SOURce:]VOLTage:PROTection:OVER
where = overvoltage protection limit

Description: Sets overvoltage protection limit. Overvoltage protection setpoint is stored in non-volatile memory;

value is restored upon power-up.

B.55

[SOURce:]VOLTage:PROTection:OVER? QUERY

VOLT:PROT:OVER?

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER?
Long Form: [SOURce:]VOLTage:PROTection:OVER?
Returns = overvoltage protection limit

Description: Indicates overvoltage protection limit.

B.56

[SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel] COMMAND

VOLT:PROT:OVER:STAT 0

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER:STAT[:LEV] 0
Long Form: [SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel] 0

Description: Clears overvoltage protection error.