B.16 input:ramp? query, B.17 [source:]input:protection:clear command, B.19 [source:]output[:state] command – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 4.00 to 4.xx User Manual
Page 73: B.20 [source:]output[:state]? query, B.21 [source:]output:protection:clear command, B.16, Input, B.17, Source, B.18

SERIES EL 071414
B-5
If input voltage from the UUT (unit under test) is subsequently lost, the output is shorted (all FET’s are
on). When input voltage recovers, the input changes from a short to the proper setpoint in a time
determined by the SYST:DAMP command, the source capabilities of the UUT and the cabling
between the load and the UUT. To maintain a ramp and eliminate any overshoot, ensure that
INP:CUT:VOLT is set to some value to enable the ramp on this condition. Pressing the LOAD switch
disengages the load; the LOAD indicator turns green and sending INP? returns 0 (disengaged).
See PAR. 3.15 and Figure 3-7 for details about how this command functions.
B.16
INPut:RAMP? QUERY
INP:RAMP?
Syntax:
Short Form: INP:RAMP?
Long Form: INPut:RAMP?
Returns
Description: Returns the ramp time established by INP:RAMP. This is the time needed to reach setpoint value
after the load is engaged.
B.17
[SOURce:]INPut:PROTection:CLEar COMMAND
INP:PROT:CLE
Syntax:
Short Form: [SOUR:]INP:PROT:CLE
Long Form: [SOURce:]INPut:PROTection:CLEar
Description: Resets protection from overcurrent, overpower, etc.
B.18
[SOURce:]INPut:PROTection:SHORt[:STATe] COMMAND
INP:PROT:SHOR
Syntax:
Short Form: [SOUR:]INP:PROT:SHOR[:STAT]
Long Form: [SOURce:]INPut:PROTection:SHORt[:STATe]
Description: Applies maximum drive to FETs, effectively shorting the input.
B.19
[SOURce:]OUTPut[:STATe] COMMAND
OUTP
Syntax:
Short Form: [SOUR:]OUTP[:STAT]
where
Description: Used to engage or disengage the load from the UUT. When set to 1 the load engages, when set to
0 the load disengages.
B.20
[SOURce:]OUTPut[:STATe]? QUERY
OUTP?
Syntax:
Short Form: [SOUR:]OUTP[:STAT]?
Long Form: [SOURce:]OUTPut[:STATe]?
Returns
Description: Indicates whether load is engaged or disengaged from the UUT. When set to 1 the load is
engaged, when set to 0 the load is disengaged.
B.21
[SOURce:]OUTPut:PROTection:CLEar COMMAND
OUTP:PROT:CLE
Syntax:
Short Form: [SOUR:]OUTP:PROT:CLE
Long Form: [SOURce:]OUTPut:PROTection:CLEar
Description: Resets protection from overcurrent, overpower, etc.
B.22
[SOURce:]OUTPut:PROTection:SHORt[:STATe] COMMAND
OUTP:PROT:SHOR
Syntax:
Short Form: [SOUR:]INP:PROT:SHOR[:STAT]
Long Form: [SOURce:]INPut:PROTection:SHORt[:STATe]
Description: Applies maximum drive to FETs, effectively shorting the output.