B.88 system:communicate:lan:mac? query, B.89 system:communicate:lan:mode command, B.90 system:communicate:lan:mode? query – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 4.00 to 4.xx User Manual
Page 84: B.91 system:communicate:lan:subnetmask command, B.92 system:communicate:lan:subnetmask? query, B.93 system:damping command, B.88, System:communicate:lan, B.89, B.90

B-16
SERIES EL 071414
B.88
SYSTem:COMMunicate:LAN:MAC? QUERY
SYST:COMM:LAN:MAC?
Syntax:
Short Form: SYST:COMM:LAN:MAC?
Long Form: SYSTem:COMMunicate:LAN:MAC?
Returns:
Description: Returns the hex MAC address of the unit if the ethernet (E suffix) option is installed; otherwise
returns 00
H
.
B.89
SYSTem:COMMunicate:LAN:MODE COMMAND
SYST:COMM:LAN:MODE
Syntax:
Short Form: SYST:COMM:LAN:MODE [FIX | DCHP]
Long Form: SYSTem:COMMunicate:LAN:MODE [FIXed | DCHP]
Description: Determines method used to obtain IP address for LAN communication.
SYST:COMM:LAN:MODE:FIX (default) configures the LAN port to use a static (fixed) IP address
entered from the front panel. SYST:COMM:LAN:MODE DCHP configures the LAN port for the stan-
dard DCHP hub required interface; uses IP address in the 192.168.x.x range compatible with most
default hub configurations.
B.90
SYSTem:COMMunicate:LAN:MODE? QUERY
SYST:COMM:LAN:MODE?
Syntax:
Short Form: SYST:COMM:LAN:MODE?
Long Form: SYSTem:COMMunicate:LAN:MODE?
Returns: [FIXed | DCHP|
Description: Returns IP Mode (method of finding the IP Address used during LAN communication); see
B.91
SYSTem:COMMunicate:LAN:SUBNetmask COMMAND
SYST:COMM:LAN:SUBN
Syntax:
Short Form: SYST:COMM:LAN:SUBN
Long Form: SYSTem:COMMunicate:LAN:SUBNetmask
Where: = numbers from 0 to 255 comprising the Subnet Mask
Description: Sets the Subnet Mask to be used during LAN communication.
B.92
SYSTem:COMMunicate:LAN:SUBNetmask? QUERY
SYST:COMM:LAN:SUBN
?
Syntax:
Short Form: SYST:COMM:LAN:SUBN?
Long Form: SYSTem:COMMunicate:LAN:SUBNetmask?
Returns:
Description: Returns the Subnet Mask used during LAN communication.
B.93
SYSTem:DAMPing COMMAND
SYST:DAMP
Syntax:
Short Form: SYST:DAMP x
Long Form: SYSTem:DAMPing x
Where x = integer from 0 (minimum damping) to 7 (maximum damping) except units with firmware ver-
sion suffix B2 and lower accept only 0 to 5(maximum)
Description: Inserts capacitance required to damp oscillation. Increased damping reduces the tendency for
oscillation and reduces response time to high speed transients. Units shipped from the factory are
shipped with SYST:DAMP set to 4. See PAR. 3.14 for an explanation of damping as well as a recom-
mended procedure for adjusting damping.