beautypg.com

Recall, File type/source/destination, Recalling the default panel settings – GW Instek GDS-1000 Series User Manual User Manual

Page 87

background image

SAVE/RECALL

87

Recall

File type/source/destination

Item

Source

Destination

Default panel
setup

Factory installed
setting

Current front panel

Reference
waveform

Internal memory: A, B

Current front panel

Panel setup
(DSxxxx.set)

Internal memory: S1 ~
S15

External memory: SD
card

Current front panel

Waveform data
(DSxxxx.csv)

Internal memory: W1 ~
W15

External memory: SD
card

Reference waveform
A, B

SD Card
restriction

The GDS-1000 series accept the following SD card.
Size: 2GB or less
Format: FAT or FAT32

Recalling the default panel settings

Procedure

1. Press the Save/Recall key.

Save/Recall

2. Press Default Setup. The

factory installed setting will
be recalled.

Setting contents

The following is the default panel setting contents.

Acquisition

Mode: Normal