Rear panel overview, Cv/cc crossover characteristics – GW Instek SPD-3606 User Manual

Page 9

background image

OVERVIEW

17

Rear Panel Overview

BEF ORE REPLACING FUSE

DISCONNECT POWER COR D

WARNING

230V

FUSE RATING

AS SPE CIFIED

250V

T10A

REP LACE FUSE

115V

AC

50/60 Hz

550 WAT TS
900 VA MAX

CH3

CH2

CH1

O.V.P. SET

NORMAL

ON

OFF

SER. NO. LB

OVP Setting
Point

Remote Control
Terminal

Power Cord / Fuse
Socket

Cooling Fan

Remote control
terminal

Accepts remote output On/Off
control connection. For details, see
page39.

OVP setting point

CH3

CH2

CH1

O.V.P. SET

NORMAL

Activates Over Voltage Protection
(OVP) and sets the protection
threshold for channel1/2/3. For
OVP setup details, see page22.

Power cord / fuse
socket

The power cord socket accepts the
AC mains: 115V/230V, 50/60Hz.
For power up details, see page20.

The fuse holder contains the AC
main fuse. For fuse replacement
details, see page57.

SPD-3606 User Manual

18

CV/CC Crossover Characteristics

Background

SPD-3606 automatically switches between constant
voltage mode (CV) and constant current mode
(CC), according to load condition.

When the current level is smaller than
the output setting
, SPD-3606 operates
in Constant Voltage mode. The
indicator on the front panel turns green
(C.V.) The Voltage level is kept at the
setting and the Current level fluctuates
according to the load condition until it
reaches the output current setting.

C.V.

C.C.

When the current level reaches the
output setting
, SPD-3606 starts
operating in Constant Current mode.
The indicator on the front panel turns
red (C.C.) The Current level is kept at
the setting but the Voltage level
becomes lower than the setting, in order
to suppress the output power level
from overload. When the current level
becomes lower than the setting, SPD-
3606 goes back to the Constant Voltage
mode.

C.V.

C.C.

Diagram

Vmax

Imax

Constant

Voltage

Constant

Current

Vout

Iout