beautypg.com

Ndex, Declaration of conformity – GW Instek SPD-3606 User Manual

Page 31

background image

APPENDIX

61

Declaration of Conformity

We
GOOD WILL INSTRUMENT CO., LTD.
(1) No.7-1, Jhongsing Rd., Tucheng City, Taipei County, Taiwan
(2) No. 69, Lu San Road, Suzhou City (Xin Qu), Jiangsu Sheng, China
declare, that the below mentioned product
Type of Product: Power Supply
Model Number: SPD-3606
are herewith confirmed to comply with the requirements set out in the
Council Directive on the Approximation of the Law of Member States
relating to Electromagnetic Compatibility (2004/108/EC, 89/336/EEC,
92/31/EEC, 93/68/EEC) and Low Voltage Directive (73/23/EEC,
93/68/EEC).
For the evaluation regarding the Electromagnetic Compatibility and
Low Voltage Directive, the following standards were applied:

EMC

EN 61326-1: 2006 Electrical equipment for measurement, control and
laboratory use –– EMC requirements
Conducted Emission
Radiated Emission

ClassA

Electrostatic Discharge

EN 55011: 1998 + A1:1999 +
A2:2002

EN 61000-4-2: 1995 + A1:1998 +
A2:2001

Current Harmonics
EN 61000-3-2: 2000 + A2:2005

Radiated Immunity
EN 61000-4-3: 2002 + A1:2002

Voltage Fluctuations
EN 61000-3-3: 1995 + A1:2001
+A2:2005

Electrical Fast Transients
EN 61000-4-4: 2004

------------------------- Surge

Immunity

EN 61000-4-5: 1995 + A1:2001

------------------------- Conducted

Susceptibility

EN 61000-4-6: 1996 + A1:2001

-------------------------

Power Frequency Magnetic Field
EN 61000-4-8: 1993 + A1:2001

-------------------------

Voltage Dip/ Interruption
EN 61000-4-11: 2004

Safety

Low Voltage Equipment Directive 73/23/EEC & amended by 93/68/EEC
Safety Requirements
IEC/EN 61010-1: 2001

SPD-3606 User Manual

62

I

NDEX

block diagram, system .............. 11

caution symbol............................. 5

cleaning the instrument .............. 7

constant current mode .............. 18

constant voltage mode.............. 18

cooling fan.................................. 20

noise level spec ............................. 60

safety instruction ............................ 6

CV/CC

indicator overview ....................... 16

overview ........................................ 18

default setting for verification . 41

EN 55011..................................... 61

EN 61000..................................... 61

EN61010

declaration of conformity............ 61

measurement category .................. 6

pollution degree.............................. 7

environment

operation.......................................... 7

specification................................... 60

storage .............................................. 7

front panel diagram .................. 14

fuse

rating .............................................. 57

replacing ........................................ 57

safety instruction ............................ 6

socket overview ............................ 17

ground symbol............................. 5

list of features ............................. 10

load connection

independent mode ....................... 26

procedure....................................... 24

tracking parallel............................ 36

tracking series ......................... 30, 33

wire type ........................................ 24

meter

ch1/ch3 switch.............................. 28

faq.................................................... 56

OVP mode ..................................... 22

multimeter for verification ....... 40

output current

recording table ........................ 54, 55

specification................................... 59

verification..................................... 47

output on/off

faq.................................................... 56

key overview................................. 14