Specification – GW Instek SPD-3606 User Manual
Page 30
APPENDIX
59
Specification
Output Ratings
CH1/CH2
Independent
0 ~ 30V / 0 ~ 6A
0 ~ 60V / 0 ~ 3A
CH1/CH2
Series
0 ~ 60V / 0 ~ 6A
0 ~ 120V / 0 ~ 3A
CH1/CH2
Parallel
0 ~ 30V / 0 ~ 12A
0 ~ 60V / 0 ~ 6A
CH3
0.1 ~ 5V / 3A
Line
≤ 0.01% + 3mV
Voltage
Regulation
Load
≤ 0.01% + 5mV
(rating current ≤ 6A)
≤ 0.01% + 8mV
(rating current ≤ 12A)
Ripple & Noise
≤ 5mVrms (5Hz ~ 1MHz)
≤ 50mV
P-P
(20Hz ~ 20MHz)
Recovery
Time
≤ 100µs (50% load change,
minimum load 0.5A)
Current
Regulation
Line
≤ 0.2% + 3mA
Load
≤ 0.2% + 3mA
Ripple & Noise
≤ 3mArms
Tracking
Operation
Tracking Error
≤ 0.5% + 10mV of Master
Series
Regulation
≤ 300mV
Ripple
&
Noise
≤ 10mVrms (5Hz ~ 1MHz)
≤ 100mVpp (20Hz ~ 20MHz)
SPD-3606 User Manual
60
Output On/Off
Response Time
Voltage Up
(10% ~ 90%)
≤ 100ms (≤95% rating load)
Voltage
Down
(90% ~ 10%)
≤ 100ms (≥10% rating load)
OVP
Accuracy
± (0.5% of reading + 0.5V)
Meter Type
3 ½ digits 0.5" LED display
Accuracy
± (0.5% of reading + 2 digits)
Resolution
100mV/10mA
Insulation
Chassis and
Terminal
100MΩ or above (DC 1000V)
Chassis and AC
cord
100MΩ or above (DC 1000V)
Voltage
≤ 100ppm/°C+3mV
Temperature
Coefficient
Current
≤ 150ppm/°C+3mA
Remote Control
Output On/Off
Fan Noise
≤ 50dB
Operation
Environment
Ambient temperature 0 ~ 40°C
Relative humidity ≤ 80%
Storage
Environment
Ambient temperature –10 ~ 70°C
Relative humidity ≤ 70%
Power Source
AC 115V/230V±15%, 50/60Hz
Accessories
User manual x 1, Power cord x 1
Test lead GTL-104 x 2, GTL-105 x 1
Dimensions
255 (W) x 145 (H) x 265 (D) mm
Weight
Approx. 6kg