I2c bus trigger settings, C bus trigger settings – GW Instek GDS-2000A series Option User Manual User Manual

Page 70

background image

GDS-2000A Series Options Manual

70

2. Press Number of Bytes from the side

menu and choose the number of
bytes for the data.

UART

1~10 Bytes

3. Press Data from the side menu to

edit the triggering data.

To edit the data, use the Variable
knob to highlight a binary or hex
digit and press Select. Use the
Variable knob to choose a value for
the digit and press Select to
confirm.

VARIABLE

Binary

0,1,X (don’t care)

Hex

0~F, X (don’t care)

ASCII

ASCII characters for
the equivalent Hex
characters 00 to FF

The Trigger on settings will be reflected on the
Trigger Configuration icon.

I

2

C Bus Trigger Settings

The I

2

C bus trigger conditions can be set at any time after the bus

settings has been set to 1

2

C.

Panel Operation

1. Set the Bus to I

2

C in the bus menu. Page 56

2. Press the Trigger Menu key.

Menu

3. Press Type from the bottom menu.