background image

LOGIC ANALYZER

47

6. If you wish to define which channels are

assigned to the bus, press Select Signal from the
side menu and select the bit that wish to assign.

Channel 1 is

currently

assigned to bit 1.

7. Next, press Select Ch and select

which channel is assigned to the
bit selected above.

8. Repeat steps 6 and 7 for any remaining bits and

for the clock, if enabled.

Threshold Configuration

Background

The threshold levels for the parallel bus can be set
to either a user-defined threshold level or to pre-
set threshold.

Operation

1. Press Thresholds from the bottom

menu.

2. Press Select from the side menu

and select a digital channel.

3. Press Choose Preset to select a pre-

set logic threshold for the selected
channel.

Logic Type

Threshold

TTL

1.4V

5.0V CMOS

2.5V