**Password Setup**


Enter a new password for this
controller and press ENTER:

New Password: 0000

**PROGRAMS & SECURITY**


(1)Seasonal Program = 1

(2)Program Name = PROGRAM1

(3)Copy to Program = 2 (4)Enter to Proceed

(5)Change Password

**DIAGNOSTICS**

"

For Qualified Technician Use Only:
(1)Power Ventilation Auxilary SWX:

(2)Ignore Inlet #1 Auxiliary SWX = Yes
(3)Ignore Inlet #2 Auxiliary Swx = Yes


(4)Natural Ventilation Auxiliary SWX:

(5)Ignore Unit #1 Auxiliary SWX = Yes
(6)Ignore Unit #2 Auxiliary Swx = Yes


(7)Feed Level Sensor:

(8)Maximum Range = 26.00 ft

(9)Dead Zone = 1.50 ft


(10)GPAD12 = 115

GPAD13 = 105

GPAD14 = 98

GPAD15 = 90


(11)Soft Resets = 0
(12)Voltage Resets = 0
(13)Hard Resets = 0

7.13 Seasonal Programs & Password Setup

The Programs & Security screen is used to change programs, copy the settings of one program into another
program or set the password to access applicable screens.
(1) Seasonal Programs – Select Program 0, 1, or 2 for the current operating program. This selection can

also be used to COPY FROM the
Seasonal Program number to the
selected program number shown in the
item 3 below.

(2) Program Name – The program name

can be changed to include a special title,
letters, numbers, and characters up to 8
digits in length.

(3) Copy to Program – Enter the COPY TO program

number (0, 1, or 2).

(4) Enter to Proceed – When “Enter to Proceed” is

selected and the ENTER button is pressed, the Copy to
Program number programming contents is replaced
with the programming contents of the Seasonal
Program number.
NOTE: This action is not reversible.

(5) Change Password – Select “Change Password” for changing the existing password for the Controller.

The four digits will allow a numeric password from 0001 to 9999. Changing the Password to 0000
disables the locks until the password is changed to a number between 0001 and 9999.
NOTE: Record the password in a convenient retrievable location.

7.14 Diagnostics

The Diagnostics screen is for qualified technician use only and can only be changed by using the service
code. Contact the local dealer for assistance.
(1) Power Ventilation Auxiliary

SWX - Setting these options to
Yes will ignore the indication from
the curtain switch. This feature
will totally ignore the auxiliary
switches on the PT machines when
answered yes.

Note: This must be answered 'No' and

the open auxiliary switch of the
vent machine must be connected
in order to use the feature of
running the tunnel curtain with
the vents during Power
ventilation when the pressure is
to high and the vents are
completely open.

(2) Ignore Inlet #1 Auxiliary Switch

- Yes or No

(3) Ignore Inlet #2 Auxiliary Switch

- Yes or No

(4) Natural Ventilation Auxiliary SWX - Setting these options to Yes will ignore the indication from the

curtain switch. This feature will totally ignore the auxiliary switches on the PT machines when
answered "Yes".

Note: The auxiliary switches must be connected and this answered to no in order for the control to enter

into natural ventilation.

(5) Ignore Unit #1 Auxiliary Switch - Yes or No
(6) Ignore Unit #2 Auxiliary Switch - Yes or No