Part No. 4801-5331 Rev 2-08

Evolution 1200

17 of 64

"

(1)DAY (2)HIGH TEMP (3)AVE (4)LOW TEMP

21 71.0°-12:34p

66.3°

61.6°–12:34a

20 71.0°-12:34p

66.3°

61.6°–12:34a

.

. .

.

. .

.

. .

.

. .

1 71.0°-12:34p

66.3°

61.6°–12:34a

"

(1)# (2)STATUS (3)MODE

(4)RTEMP (5)ON (6)OFF (7)TIME

.

.

.

.

.

.

.

V1

50%

Light

Ramp

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

V2

75%

CStir

88.7°

76.4°

74.0°

None

.

.

.

.

.

.

.

.

.

.

.

.

.

.

Select and Press ‘Enter’:

Room Temperature

Stage 1 – 16 RunTimes

Humidity

Stage 17 – 32 RunTimes

Water Usage #1

Stage 33 - 48 RunTimes

Water Usage #2

Stage 49 – 64 RunTimes

Ventilation Mode

PowerTrack RunTimes

Feed History

Alarm Log

(5) ON – The temperature at which the stage operates.
(6) OFF and (7) TIME – This column indicates if the machine is fully closed. When the machine is on

the closed auxiliary switch, this column will display “Yes”.

6.4.4 Variable

Stages

The Variable stages are used to control devices (i.e. fans & lights) with a variable capability. The same V1
& V2 settings shown in this screen are also shown in the top portion of the Onboard On/Off Stages screen.












(1) # - The Stage bank either V1 or V2.
(2) Status - This is the current run percentage that the device is operating.
(3) Mode – Indicates how the stage is programmed: CSTIR, CNEG, CNEGT, CTUN or LIGHT.
(4) Rtemp –The Rtemp column indicates the current temperature from which the stage is operating.
(5) ON –
The ON column indicates the maximum ON temperature at which the variable speed fan will

reach full speed.

(6) OFF -The OFF column indicates the minimum ON temperature at which the fan will run at minimum

speed.

(7) Time – None, Min1, Min2, Var or Always ON (ON). Always ON when Rtemp is below MIN ON.

6.5 Historical

Data

This screen provides access to historical data. Highlight the selection and press the ENTER button on the
EDITOR panel.
NOTE: The Historical Data for Onboard Stages 1 thru 8 will be found in “Stage 1-16 Runtimes”.









6.5.1 Room

Temperature

This screen shows the highest and lowest
room temperature for each day for up to 99
days. The last day reported will appear at the
top of the list. The list can contain data up to
99 days. After displaying 99 days, oldest data
will be deleted.
(1) Day –
The specific day in the growout period. Values = 1 day to 99 days.
(2) High Temp – The high recorded temperature and the time of day that it occurred.
(3) AVE – The average recorded temperature for the day.
(4) Low Temp - The low recorded temperature and the time of day low temperature occurred.