7 alarm status – Hired-Hand Evolution Series 1200 User Manual
Page 21
![background image](/manuals/362893/21/background.png)
Part No. 4801-5331 Rev 2-08
Evolution 1200
21 of 64
6.7 Alarm
Status
The ALARM column lists the elements and sensors that are available. For the High and Low temperatures
and High and Low pressure, the Cycle Pressure the current Alarm Limits are shown. For all entries the
STATUS and the LAST REPORTED alarm are indicated. To change the ALARM LIMIT use the Editor
arrows to highlight the desired entry and the Plus (+) and Minus (-) buttons to increase or decrease the
desired limit.
(1) High Temperature Limit & Status - The high temperature setting at which the alarm relay will activate.
See Section 6.7.1.
(2) Low Temperature Limit & Status - The low temperature setting at which the alarm relay will activate.
See Section 6.7.2.
(3) Cycle Pressure Limit & Status - The pressure setting at which the alarm relay will activate provided the
pressure differential is not seen during the timer period.
(4) High Pressure Limit & Status - The High Pressure alarm will send a signal to your existing alarm system
when the pressure exceeds the High Pressure Setpoint for greater than 45 seconds. (High Negative
Pressure) This alarm warns if the vents did not open for some reason (Automatically enabled during
Tunnel).
(5) Low Pressure Limit & Status – When the Low Pressure alarm is enabled, it becomes a constant pressure
alarm. It will send a signal when pressure drops below the Low Pressure setpoint at any time for greater
than 45 seconds. Setting the Low Pressure alarm setpoint to "OFF" prevents the alarm from sounding.
(6) High Rate - High water usage rate. Alarm if units per hour exceed. One or two water meters (#1 or #2) can
be monitored.
"
TEMPERATURE LIMIT STATUS LAST ALARM
(1)High Temp
85.0
°
OK 08/15-10:36p
(2)Low Temp
65.0
°
OK
08/10-03:36p
PRESSURE LIMIT STATUS LAST ALARM
(3)Cycle Press 0.04 Off 08/09-07:36p
(4)High Press 0.15 Off 07/22-01:36p
(5)Low Press 0.03 Off 07/13-06:36p
WATER ALARMS LIMIT
STATUS
LAST ALARM
(6)High Rate #1 100/hr
OK 01/01-12:00a
(7)Low Rate #1
25/hr
OFF
01/01-12:00a
(6)High Rate #2 100/hr
OK 01/01-12:00a
(7)Low Rate #2
25/hr
OFF
01/01-12:00a
FEED ALARMS LIMIT STATUS LAST ALARM
(8)Auger Run1
10min
OFF
01/01-12:00a
(9)Auger Run2
10min
OFF
01/01-12:00a
SYSTEM STATUS STATUS
LAST ERROR
(10)Tunnel Vent
---- OK
07/12-02:36p
(11)Growout Day
---- OK
07/31-05:36p
(12)Local Network---- OK
07/27-05:36p
(13)Back-Up Limits -- OK
07/31-05:36p
(14)Sensor 1 ---- OK
07/27-05:36p
(14)Sensor 2 ---- OK
06/10-09:36p
(14)Sensor 3 ---- OK
06/11-01:36p
(14)Sensor 4 ---- OK
06/13-06:36p
(14)Sensor 5 ---- OK
06/13-03:36p
(14)Sensor 6 ---- OK
06/21-03:36p
(14)Sensor 7 ---- OK
06/17-02:36p
(14)Sensor 8 ---- OK
06/13-10:36p
(15)Outside ---- OK
07/13-02:31p
NOTE: The High and Low
temperature reading is taken from
the Sensors for Display in "Sensor
Setup" of the Program Setup Screen.
Proceed
to Detail
Screens