**STATIC PRESSURE SETTINGS**

(1)Vent Anticipation = On

(2)Learn Times = Yes

(3)Time before fan starts = 5 s

(4)Time after fan starts = 5 s


(5)Reaction Delay = 5 seconds
(6)Pressure Differential = 0.02

(7)Pressure Ramping = On
(8&9)Target Press. = 0.04 @ High Temp = 80.0°
(10&11)Target Press. = 0.09 @ Low Temp = 50.0°

** Feed Level Module Setup **

(1)Bin 1:
(2)Diameter = 6 ft

(3)Cap Angle = 30°

(4)# of Rings = 1

(5)Ring Height = 2.67ft

(6)Feed wt: 00 lb (7)Bin ht: 9.07 ft
(8)Bin 2:
(9)Diameter = 6 ft (10)Cap Angle = 30°
(11)# of Rings = 1

(12)Ring Height = 2.67ft

(13)Feed wt: 00 lb (14)Bin ht: 9.07 ft

(5) Value – Current temperature reading.
(6) Adjusted – This will indicate if the sensor temperature has been calibrated and the amount of re-

calibration.

7.3

Feed Level Sensors

The Feed Level Module Setup screen sets
the parameters required to monitor feed
bins.
(1) Bin 1 - These settings provide the feed

level sensor at Bin #1 with necessary
information to calculate the
approximate feed weight and height.

(2) Diameter – Feed Bin #1 diameter =

6, 7, or 9 ft.

(3) Cap Angle – Feed Bin #1 cap angle at

the top of the bin = 30° or 40°

(4) # of Rings – Feed Bin #1 number of rings = 1, 2, 3, 4, or 5
(5) Ring Height - Feed Bin #1 ring height = Measurement from the top/center of one ring to the

top/center of the next ring.

(6) Feed wt - Feed Bin #1 feed weight = The feed weight is calculated by using the entered bin size

information and the current feed level module results.

(7) Bin ht - Feed Bin #1 bin height = The bin height is calculated by using the entered bin size

information.

(8) Bin 2 - These settings provide the feed level sensor at Bin #2 with necessary information to calculate

the approximate feed weight and height.

(9) Diameter – Feed Bin #2 diameter = 6, 7, or 9 ft.
(10) Cap Angle – Feed Bin #2 cap angle at the top of the bin = 30° or 40°
(11) # of Rings – Feed Bin #2 number of rings = 1, 2, 3, 4, or 5
(12) Ring Height - Feed Bin #2 ring height = Measurement from the top/center of one ring to the

top/center of the next ring.

(13) Feed wt - Feed Bin #2 feed weight = The feed weight is calculated by using the entered bin size

information and the current feed level module results.

(14) Bin ht - Feed Bin #2 bin height = The bin height is calculated by using the entered bin size

information.

7.4 Ventilation

Inlets

The Static Pressure setting sets the parameters necessary to operate the vents.

(1) Vent Anticipation - When vent

anticipation is turned ON, the vents will
start opening before a negative ventilation
stage turns on and continue to open until
the vent opening necessary for the desired
target pressure is achieved.

(2) Learn Times – When learn times “Yes” is

selected, the controller will automatically
adjust the time (seconds) before and after
the fans turn ON depending on the static
pressure. NOTE: This feature is disabled
in Optimum Mode.

(3) Time before fan starts – The number of

seconds before a negative ventilation
stage turns ON that the vents will start
opening.

(4) Time after fan starts – The number of seconds after a negative ventilation stage turns ON that the vents

will continue to open allowing the fans to increase to full speed.