2 onboard stages, 3 natural ventilation stages – Hired-Hand Evolution Series 1200 User Manual

Page 16

background image

Part No. 4801-5331 Rev 2-08

Evolution 1200

16 of 64

"

. .

.

.

. .

.

. .

.

.

. .

.

(1)# (2)STATUS (3)MODE (4)RTEMP (5)ON (6)OFF (7)TIME
TUN OFF

CTUN

79.4°

85°

80°

1 On

Light

Ramp

2 On

Cstir

79.6° 76°

95°

None

. .

.

.

. .

.

----------- (8)TARGET

70°

---------

. .

.

.

. .

.

16 On

Cstir 79.6° 76°

95°

Min1

"

(1)# (2)STATUS (3)MODE

(4)RTEMP (5)ON (6)OFF (7)TIME

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

U1

On

NAT

CLOSE

73.0°

72.0°

CLOSED: NO

U2

On

N&T

CLOSE

73.0°

72.0°

CLOSED: NO

U1

Off

NAT

OPEN

73.0°

74.0°

CLOSED: NO

U2

Off

N&T

OPEN

73.0°

74.0°

CLOSED: NO

.

.

.

.

.

.

.

.

.

.

.

.

.

.

6.4.2 Onboard

Stages

The Onboard On/Off stages 1 thru 6 are used for devices that do not need a variable speed capability.
Stages 7 & 8 are user selectable to be either Variable Speed Fan Outputs or regular On/Off Stages. Refer
to Section 8.2 for Stages 7 & 8 mode selection diagrams and details. This On/Off Stages screen shows you
how onboard stages 1 thru 8 and also the variable stages V1 & V2 are set. For expansion stages, refer to
Sections 6.9 and 7.8.
(1) # - Identifies the On\Off stage number, variable stage number, or Tunnel and lists them in the order of

priority. Tunnel is not a stage like the Stage Master and Vent Master. This parameter is set in the
tunnel ventilation of Program Setup screen. See Section 7.7, Tunnel Ventilation.















(2) Status - Indicates if the stage is

currently Timed, On, or Off.

(3) Mode - This column indicates how the

stage is programmed. Any stage
can be set to any of these modes.
The available stage options are:
Off, Heat, CSTIR, CNEG,
CNEGT, CTUN, LIGHT, FEED or
CEVAP.

(4) Rtemp - The Rtemp column will

indicate the current temperature
from which the stage is operating.

(5) On – The current temperature setting for the on

point temperature of the stage.

(6) Off - The current temperature setting for the off

point temperature of the stage.

(7) Time - This column indicates if a stage is on a

timer and shows the different timers you are
allowed to put a stage on. The timer options
are: None, Min1, Min2, Var, Cool, or Opt
xx.

(8) Target – Target Temperature.

6.4.3 Natural Ventilation Stages

Natural Ventilation stages are used to open and close side curtains to allow natural ventilation.












(1) #- The stage bank either U1 or U2.
(2) Status - This column will indicate whether the machine is Off, Opening or Closing.

(3) Mode – The mode column indicates how the machine will be operating. It will be a natural curtain

"NAT" or a natural and tunnel "N&T" machine (U2 only). OPEN or CLOSE will be shown
beside the mode to show whether the specific line refers to the Open or Close function.

(4) Rtemp –The Rtemp column will indicate the current temperature the curtain machine is operating from.