Part No. 4801-5331 Rev 2-08

Evolution 1200

20 of 64

6.5.8 Alarm

Log

This screen shows the list of the past 20 alarms and status information starting with the most recent
occurrence.
(1) Alarm

Description –
The alarm
problem area.

(2) Alarm Status –

The alarm
status (Failure
or Correted).

(3) Date of Alarm –

The date the
alarm
occurred or was corrected.

(4) Time of Alarm – The time the alarm occurred or was corrected.

6.6 Back-Up

Status

The Back-Up status shows the status information concerning back-up operation.











NOTE: This is the high and low limit of the Evolution Back-Up system. These setting are set in the Back-Up

system.

(1) Back-up High Limit – The high temperature

limit at which the Back-up stages will start
turning on cool stages.

(2)Target Temperature – Backup target

temperature.

(3) Back-Up Low Limit - The low temperature

limit at which the Back-up will turn on the heat
stage.

(4) Back-Up Run % The Back-up timer

percentage.

NOTE: This is the timer percentage of the

Evolution Back-Up system. This setting is set in
the Back-Up system. If the Back-Up fails to
communicate with the Evolution 1200 control
the Back-Up will display an LnE. At this point
the Back-Up will take over minimum ventilation
by running all Cool 1 circuits on this timer. This
percentage is how long the fan will run out of
five minutes.

(5) Cycle 5 Minutes –The cycle time of the back-up

stages is 5 minutes.

(6) Warning if Back-Up – If Backup settings are

set that far away from target, Back-up status light
will flash.

(7) Alarm if Back-Up -Same as above but will also

set off auxiliary alarm contact.

** Alarm Log **

"

1 (1)Tunnel Vent

(2)Corrected @

(3)2/ 5

(4)1:26p

2

Low Press

Failure @

2/ 5

1:09p

3

Lo Water Rate

Corrected @

2/ 3

3:39p

4

Cycle Press

Failure @

2/ 1

4:15a

5

Low Temp

Corrected @

1/ 30

3:09p

6

Lo Water Rate

Corrected @

1/ 27

12:38a

7

Lo Water Rate

Corrected @

1/ 21

7:45a

8

Lo Water Rate

Corrected @

1/ 17

9:52p

9

Low Pressure

Failure @

1/ 15

5:21p

10

Max Runtime1

Corrected @

1/ 10

8:27a

(1)Back-Up High Limit: 86°

(2)Target Temperature: 70°
(3)Back-Up Low Limit: 60°

(4)Back-Up Run %: 0%

(5)Cycle: 5 minutes

(6)Warning if Back-Up +/- 11° from Target
(7)Alarm if Back-Up +/- 12° from Target