6 cool evaporative properties – Hired-Hand Evolution Series 1200 User Manual
Page 36

Part No. 4801-5331 Rev 2-08
Evolution 1200
36 of 64
** Cool Evaporative Properties **
"
These stages typically operate
Evaporative Cooling Systems. The
following are additional properties:
(1)Only Operate During Tunnel Vent = No
(2)Time Override:
Allow to Operate Always
Time falls between 12:00p - 5:00p
(3)Humidity Override:
Allow to Operate Always
Humidity < 75%
(4)Growout Day Override:
Allow to Operate Always
Growout Day > 14
(5)Outside Temperature Override
Allow to Operate Always
Outside Temperature > Target +10.2°
(2) Growout Day Override – During the first days of the growout period, especially during brooding, the
Evolution 1200 can be set to only allow the cool tunnel stages to operate after a specified number
of days in the growout period. When set to Only While, the Growout Day Override will allow the
stages to operate only while the growout day is greater than the day you set. Otherwise when set
to Always, the day of growout will not affect the stages.
(3) Outside Temperature Override - When set to Only While the Outside Temperature Override will
allow the stages to operate only while the outside temperature is greater than the target plus or
minus the desired setting. Otherwise when set to Always the outside temperature will not affect
the stages.
7.10.6 Cool Evaporative Properties
Cool Evaporative Properties allow for setting several override functions. Take note when setting the
properties. All options must be true before the stage is allowed to operate.
For example if all options are set to Only While, then all options will have to be true or in the range before
the stage is allowed to operate.
(1) Only Operate During Tunnel
Vent –Setting this to “Yes”
will only allow the
evaporative cooling stages
to operate during tunnel.
Otherwise on “No” will
allow the stages to operate
while not in tunnel. For
example on misting Hogs
during natural ventilation.
(2) Time Override – When set to
Only While, the Time
Override will allow the
stages to operate only while
the time is between the
times you set. Otherwise
when set to Always, the
time will not affect the
stages.
(3) Humidity Override - Run while
humidity is less than XX%. When set to Only While, the Humidity Override will allow the stages
to operate only while the humidity is less than the humidity you set. Otherwise when set to
Always, the humidity will not affect the stages.
(4) Growout Day Override - When set to Only While, the Growout Day Override will allow the stages to
operate only while the growout day is greater than the day you set. Otherwise when set to
Always, the day of growout will not affect the stages.
(5) Outside Temperature Override - When set to Only While, the Outside Temperature Override will
allow the stages to operate only while the outside temperature is greater than the target plus or
minus the desired setting. Otherwise when set to Always, the outside temperature will not affect
the stages.