Hired-Hand Evolution Series 1200 User Manual

Page 22

background image

Part No. 4801-5331 Rev 2-08

Evolution 1200

22 of 64

(1)High Temperature Alarm Details
(2)Alarm On/Off = Off
(3)High Temperature Limit = 81.5°
(4)Increase Limit In Tunnel = +2.0
(5)Last Alarm Statistics:
(6)Date: 02/12 (6)Time: 1:09p
(7)Cause: Sensor 1

(1)Low Temperature Alarm Details
(2)Alarm On/Off = Off
(3)Low Temperature Limit = 71.5°
(4)Last Alarm Statistics:
(5)Date: 02/12 (5)Time: 1:09a
(6)Cause: Sensor 1

(7) Low Rate - Low water usage rate. Alarm if units per hour drop below. One or two water meters (#1 or #2)

can be monitored.

NOTE: Low Alarm is disabled when lights are off.

(8) Auger Run1 - Alarm if continuous runtime of feed line #1 exceeds selected time limit.

(9) Auger Run2 - Alarm if continuous runtime of feed line #2 exceed selected time limit.

(10) Tunnel Vent - The Tunnel alarm will send a signal if for some reason the controller is unable to enter

tunnel. See Section 6.7.3.

(11) Growout Day - Status & last error (Warning only).

(12) Local Network - Status & last error.

(13) Back-Up Limits - Status & last error.
(14) Sensor 1 through 8 Limit & Status - If the sensor is disabled, this field will show “off”. If the sensor is

enabled, this field will show “OK” if the sensor is functioning properly or “fail” if the sensor is not properly
reporting the temperature. Check wiring for damage or bad connection.

NOTE: This is the status of the alarms. Once an error has occurred the LED for Alarm Status will start

blinking. Use the Navigator arrows to move down to Alarm Status. You will see what has failed. For a
detail of what caused the failure navigate down to highlight the alarm and press enter. This will give a
detail of what caused it and when it happened. High Temp, Low Temp, and Tunnel Vent have an additional
detail screen viewable by scrolling down and highlighting the desired alarm and pressing enter.

(15) Outside -If the sensor is disabled, this field will show “off”. If the sensor is enabled, this field will show

“OK” if the sensor is functioning properly or “fail” if the sensor is not properly reporting the temperature.
Check wiring for damage or bad connection.

6.7.1 High Temperature Alarm Details

The High Temperature Alarm Details lists the settings for the alarm and the last time the alarm was
sounded and the cause of the alarm.
(1) High Temperature Alarm Details – Identifies

the following information:

(2) Alarm On/Off – The status of the alarm is On

or Off.

(3) High Temperature Limit – The current

temperature setting of the High
Temperature alarm.

(4) Increase Limit In Tunnel – Increase high temperature limit during tunnel mode by this number.
(5) Last Alarm Statistics – Identifies the date, time and cause of the last alarm.
(6) Date & Time – The date and time of the last alarm. Date is given as Month/Day.
(7) Cause – Displays the reading of the high temperature that caused the alarm.

Possible Reasons for High Temperature False Alarm Conditions:

• If the same sensor causes multiple alarms, check the location of the sensor and wiring for possible

damage. Also insure that the limit is properly set for the target and room temperature.

6.7.2 Low Temperature Alarm Details

The Low Temperature Alarm Details lists the settings for the alarm and the last time the alarm was
sounded and the cause of the alarm.
(1) Low Temperature Alarm Details – Identifies

the following information:

(2) Alarm On/Off – The status of the alarm is On or

Off.

(3) Low Temperature Limit - The current setting

of the Low Temperature alarm limit.

(4)Last Alarm Statistics - Identifies the date, time

and cause of the last alarm.

(5) Date & Time – The date and time of the last alarm. Date is given as Month/Day.