Part No. 4801-5331 Rev 2-08

Evolution 1200

18 of 64

Water Meter 1

"

(1)DAY (2)HIGH RATE (3)DAILY TOTALS
41 24/hr-12:00p 240
40 20/hr-12:34p 210
. . . .
35 10/hr-11:15p 200
. . . .
. . . .
24 15/hr-12:05p 130
. . . .
. . . .
1 5/hr-1:00p 50

NOTE: The High and Low temperature readings are taken from the Sensors for Display in "Sensor Setup"

of the Program Setup Screen.

6.5.2 Humidity

Sensor

This screen shows the highest room humidity
for each day for up to 99 days. The last day
reported will appear at the top of the list. The
list can contain data up to 99 days. After
displaying 99 days, oldest data will be
deleted.
(1) Day –
The specific day in the growout

period. Values = 1 day to 99 days.

(2) High Humidity – The highest recorded room humidity (PCB186-J14 Humidity Sensor) and the time of

day that it occurred.

6.5.3 Water Usage (#1 or #2)

This screen gives the Water Usage of the
building per day of growout, high rate, and
water total. The screen display format is
the same for either water usage #1 or #2.
(1) Day– The specific day in the growout

period. Values = 1 day to 99 days.

(2) High Rate The highest recorded

water rate and the time of day that
it occurred.

(3) Total For Each Day The total water

usage for each day of growout.

6.5.4 Ventilation

Mode

This screen shows the length of time in hours
and minutes that the Control is in different
ventilation modes. NOTE: Natural mode is
when the system is in natural ventilation and
the main curtains are open.
Transition mode is when the control is
between power and tunnel ventilation. The
control is making the adjustments needed to
go into tunnel. Tunnel mode is when the tunnel signal has been activated and the system has entered into
tunnel.
(1) Minimum Ventilation – The time spent in minimum mode. Heaters & timer fans running.
(2) Power Ventilation –
The time spent in the Power Ventilation mode.
(3) Natural Ventilation –
The time the side wall curtains are open.
(4) Transition to Tunnel –
The time required to transit to tunnel mode. (3 minutes per transition)
(5) Tunnel Ventilation –
The time spent in the Tunnel mode.







Today Yesterday
(1)Minimum Ventilation 6:07 10:31
(2)Power Ventilation 1:10 6:29
(3)Natural Ventilation 2:00 1:00
(4)Transition to Tunnel 0:03 0:09
(5)Tunnel Ventilation 0:45 4:51

"

(1)DAY (2)High Humidity
21 70%-12:34p
20 70%-12:34p
. . .
. . .
1 70%-12:34p