4 stage conditions, 1 inlet conditions – Hired-Hand Evolution Series 1200 User Manual
Page 15
![background image](/manuals/362893/15/background.png)
Part No. 4801-5331 Rev 2-08
Evolution 1200
15 of 64
Inlet
Conditions
"
#
STATUS
MODE
PRESS
OPENED
CLOSED
U1 Close Vent
0.00 No
No
U2 Close Tun
0.00 No
No
# STATUS
MODE RTEMP
ON
OFF
TIME
----------- TARGET
70°
---------
V1 0%
CTUN 79.4°
89.4 89.0
Ramp
V2 0%
Cstir 79.6° 89.4
89.0
None
1
On
Light
Ramp
2
On
Cstir 79.6° 76°
95°
None
.
. . . . .
.
16 On
Cstir 79.6° 76°
95°
Min1
Inlet Conditions
"
(1)#
(2)STATUS
(3)MODE
(4)PRESS
(5)OPENED
(6)CLOSED
U1 Open
Vent
0.04 No
No
U2 Close
Tun
0.04 No
Yes
.
. .
.
. .
.
. .
.
.
.
.
.
(17) Cycle - Cycle Time in Minutes. Cool timer is
also allowed a different timer cycle if needed.
This will be used for foggers or cool cell
systems.
(18) Min Run - The Cool Timer Minimum Run
Time percentage.
6.4 Stage
Conditions
When the Stage Conditions screen is selected by using the Navigator Select arrows, the following menu
screen is shown. Use the up and down arrows in the Editor to view the desired information. Notice that
the Light Clock and Feed Clock Stages are listed after the Inlet Conditions section. The Heat Stages are
then displayed in order of increasing ON Temperatures. The Cool stages, including the Variable Output
stages, are listed below the Target Line in order of increasing ON Temperatures.
6.4.1 Inlet
Conditions
The Inlet Conditions part of the Stage Conditions screen is used to control Power Trak operation for power
ventilation. U1 is normally for baffle boards and U2 controls tunnel inlets.
(1) #- The stage bank either U1 or U2.
(2) Status - Indicates if the Stage is Off, Opening or Closing.
(3) Mode – The mode column tells you how the machine will be operating. If it will be a vent machine
"VENT" or a tunnel machine "TUN" machine.
(4) Pressure – Indicates the pressure in the building.
(5) Opened – Indicates if the machine is fully open (Yes or No). When the machine is fully open on the
open auxiliary switch, this column will indicate a “Yes”.
(6) Closed – Indicates if the machine is fully closed (Yes or No). When the machine is fully closed on the
closed auxiliary switch, this column will indicate a “Yes”.