beautypg.com

Evolution front panel, Evolution 4000 front panel – Hired-Hand Evolution 4000 Control System User Manual

Page 8

background image

Part No. 4801-5338 Rev 01-10

Evolution 4000

8 of 86

EVOLUTION 4000 FRONT PANEL

Navigator
Buttons

Stage switches
(ON, OFF,
AUTO)

'Stage On'
Indicators

White spaces
are for stickers
to identify stage
operations

Editor Buttons

Main Display

Contrast

Adjustment

System
View

Page Display

Up & Down

Toggle

Language

Tue 15 Sep 2009 10:45a

Growout Day: 258

Ventilation Mode: Minimum

Room Temp:

71.4°

Target:

70.0°

Pressure:

0.00 wc

Target:

0.04 wc

Humidity:

0%

Target <

60%

Outside:

77.0°

Enclosure:

95.0°

Water Consumption

Feed Levels

1. 240

(10/hr)

1. 11.2ft

( 60%)

2. 280

(10/hr)

2. 5.0ft

( 23%)

PAGE for Details

5. Evolution Front Panel

The Evolution 4000 Controller cover is divided into two main areas. The main control user interface is
located on the top-half of the panel and contains the Main Display, Editor and Navigator user interface
controls. The Stage Switches are located on the bottom-half of the front panel. The Navigator is used to
select the information to be displayed in the Main Display. Once the desired information is selected in the
Navigator, the Editor is used to scan and modify the data, adjust the display contrast, page-scroll through the
displayed information screens, or toggle the displayed information between English and Spanish languages.