Replacement Harnesses and Cables (Transformer/AC Power Connections)






















































WARNING!!

Ensure The

Internal Voltage

Selection Wiring Is

Connected As

Required BEFORE

Power Is Applied

To The Controller.

230 VAC

Wiring

115 VAC

Wiring

Jumper

Connection

Required

For

230 VAC

Power

Jumper

Connection

Not

Required

For

115 VAC

Power

The EV4000 controller is factory prewired for 240 VAC. For 115 VAC Power,
disconnect both the orange and yellow wires from the orange jumper then connect
the Yellow and Orange wires to the terminal block L1 & L2 as shown above.