beautypg.com

Important – Hired-Hand Evolution 4000 Control System User Manual

Page 63

background image

Part No. 4801-5338 Rev 01-10

Evolution 4000

63 of 86

9.11 Applying Inlet Stage Labels to the Evolution 4000 Cover Label

The Stages user interface below shows the toggle switches for controlling the 40 stage relay boards.
Stages may be set/programmed as inlets to control vents & curtains. When the Manual/Auto toggle switch is placed
in Auto position, inlet opens and closes according to programmed instructions. Use the Open/Close toggle switch to
manually open or close inlet when Auto/Manual toggle switch is placed in Manual position. Under normal
circumstances the machines should be left in automatic (Auto). The Notation area is for labeling the inlet.
Each Inlet will use a pair of stage banks. The specific pair of stage banks may be chosen from any of the 40 stages
as long as the first stage is an odd number and the second stage is the very next adjoining even stage number. After
determining which pair of stages will be used, apply the Inlet Label (4501-0273) as shown below. One Inlet label
will be used for each Inlet Stage pair.

IMPORTANT!

Stages that are programmed to be open/close stages must follow two rules. First, they must be
consecutive, and second, they must start on an odd stage. The open output will always be the odd
stage and the close stage will always be the even stage.









































Manually opens or

closes inlet

Controller opens or

closes inlet

Notation Area

Toggle Switch

(Auto or Manual

Operation)

Toggle Switch
(Open or Close
Operation)

Opens Inlet
(Manual Oparation)

Closes Inlet
(Manual Oparation)