Evolution 4000

19 of 86

Refer to Section 6.4.2 & 7.9.
When Mode=Off, those stages will not
be visible on the Stage Conditions
Screen.

STAGE CONDITIONS SCREEN EXAMPLE:





















































Refer to Section 7.13.

Refer to Section 6.4.3, 7.6, & 7.11.7.

Target: The desired temp. of the building.

Enter Tun: Fans enter Tunnel at set temp.

Exit Tun: Fans exit Tunnel at set temp.

N/A: The stage is not allowed to turn on with the current set conditions.
Off: The stage is currently OFF.
On: The stage is currently ON.
Timed: The stage is currently ON with a timer.

Refer to Section 7.12.

Refer to Section 6.4.1 & 7.5.

Refer to Section 6.4.1 & 7.5.

Refer to Section 6.4.3 & 7.6.

Refer to Section 7.9 and 7.11.1.

Refer to Section 7.11.2.

Refer to Section 7.11.3.

Refer to Section 7.11.4.

(1)Stage Properties

"

# STATUS

MODE

RTEMP

ON OFF TIME

1 On

Attic

Open

2 Off Attic

Close

3 Off Vent

Open

4 On

Vent

Close

5

Off

Tunnel 1 Open

6

On

Tunnel 1 Close

7

Off

Tunnel 2 Open

8

On

Tunnel 2 Close

9

Off

Natural 1 Open

10

On

Natural 1 Close

11

On

Light

Ramp

12

On

Light

Ramp

13

Off

Feed

Sch1

14

Off

Feed

Sch2

15 Off

Heat

86.0° 77.5°

79.0° None

16 Off

Heat

86.0° 77.5°

79.0° None

17 Off

Heat

86.0° 77.5°

79.0° None

18 Off

Heat

86.0° 75.0°

77.0° None

----------- TARGET

80° ---------

19 Off

Cstir

86.0° 82.0°

81.0° Min1

20 Off

Cstir

86.0° 82.0°

81.0°

21 Off

Cstir

86.0° 82.0°

81.0°

22 Off

CNeg

86.0° 82.5°

81.0°

23 Off

CNeg

86.0° 82.5°

81.0°

24 Off

CNeg

86.0° 83.0°

81.5°

25 On

CNegT

86.0° 83.0°

82.0°

26 On

CNegT

86.0° 84.0°

83.0°

27 On

CTUN

86.0° 84.5°

83.0°

28 On

CTUN

86.0° 85.0°

84.0°

29 On

CTUN

86.0° 86.0°

85.0°

30 Off

CTUN

86.0° 88.0°

86.0°

31 Off

CTUN

86.0° 90.0°

88.0°

-----------

MAXIMUM TUNNEL FANS

----------

32 Off

CEVAP

86.0° 92.0°

87.0° Var

33 Off

CEVAP

86.0° 92.0°

87.0° Var

34

Off

Off

35

Off

Off

36

Off

Off

37

Off

Off

38

Off

Off

39

Off

Off

40

Off

Off

U1 On

NAT

CLOSE

---.- 90.0°

CLOSED:No

U2 On

NAT

CLOSE

---.- 90.0°

CLOSED:No

U3 On

NAT

CLOSE

---.- 90.0°

CLOSED:No

U4 On

NAT

CLOSE

---.- 90.0°

CLOSED:No

U1 Off

NAT

OPEN ---.- 92.0°

CLOSED:No

U2 Off

NAT

OPEN ---.- 92.0 CLOSED:No

U3 Off

NAT

OPEN ---.- 92.0 CLOSED:No

U4 Off

NAT

OPEN ---.- 92.0 CLOSED:No

--- On

Exit

Tun ---.- ---- 83.0

----

--- On

Enter

Tun ---.- 86.0 ----

----

Refer to Section 6.4.1, 7.5 & 7.8.

Refer to Section 7.11.6.

Maximum Tunnel Fans: The maximum number
of tunnel fans will be turning ON from this
point downward with hotter temperatures.

Refer to Section 7.11.5.