beautypg.com

13 setup light clocks, 1 light clock details, 14 seasonal programs & security – Hired-Hand Evolution 4000 Control System User Manual

Page 46

background image

Part No. 4801-5338 Rev 01-10

Evolution 4000

46 of 86

**PROGRAMS & SECURITY**


(1)Seasonal Program = 1

(2)Program Name = PROGRAM1

(3)Copy to Program = 2 (4)Enter to Proceed

(5)Change Password

**LIGHT CLOCK SETUP**


(1)Feed Cycle Light Override = No
(2)Feed Cycle Light Intensity = 25%

(3)Growout Schedules used by Ramp 1-4
(4)SCHEDULE (5)START DAY

1

1

2

17

3

19

4

22

5

25

(1)Light Schedule: 4

(2)Start Day = 22

(3)Number of On/Off Cycles = 4

(4)CYCLE (5)START (6)RUNTIME (7)INTENSITY (8)RAMP
1

12:00a 2:00 75% 0:10

2

10:00a 2:00 100% 0:10

3

5:00p 2:00 100% 0:10

4

10:00p 2:00 100% 0:10

7.13 Setup Light Clocks

The Light Clock Setup establishes the
parameters necessary to enable automatic control
of the house lights. On each Schedule you will
need to program a start day of when you want
the control to start using this schedule. Then you
will need to set the number of on/off cycles.
This is how many times the light clock needs to
come on in a 24-hour period. You are allowed
10 on/off cycles. Then you set the start time of
each cycle and how long that cycle needs to run.
When you are using a variable speed stage for
the lights you are allowed to set the intensity and
ramp. The intensity is the level you want the
lights to be on when your cycle comes on. The
ramp allows the light ramp up and down from
off to the intensity you have set. The ramp
applies at the beginning and the ending of the
light cycle.
(1) Feed Cycle Light Override - Turns the lights to a set intensity while running the feed program.
(2) Feed Cycle Light Intensity –
Set the light intensity percentage to occur during the feed cycle.
(3) Growout Schedules used by Ramp 1-1
- Set the number of schedules from one up to five. The next

schedule will start after you have reached the growout day that your schedule starts on.

(4) Schedule – The schedule number will automatically be set by Evolution. After the number of

Schedules have been set you will need to setup each schedule.

(5) Start Day –The starting day of each schedule.

7.13.1 Light Clock Details

Select the individual cycle in the Light
Clock Details screen and enter the start
day time that lighting is to begin and
the length and intensity of the lighting
period. This screen is also available
from the Target Conditions screen as
described in Section 6.2.
(1) Light Schedule – The selected

schedule.

(2) Start Day – Set to the growout day to start program.
(3) Number of On/Off Cycles – Enter the number of On/Off cycles desired (up to ten).
(4) Cycle –The selected cycle within the schedule.
(5) Start – The start time of the lighting cycle.
(6) Runtime- The runtime of the lighting cycle. (hours : minutes)
(7) Intensity –Set the intensity of the lights from 0% to 100%. (For use with variable units only).
(8) Ramp – If it is desired to ramp the lights, that is to slowly turn the lights on and off, enter the time

period (hours:minutes) over which to turn the lights on and off (For use with variable units).

7.14 Seasonal Programs & Security

The Seasonal Programs & Password Setup
screen is used to change programs, copy
the settings of one program into another
program or set the password to access
applicable screens.