Hired-Hand Evolution 4000 Control System User Manual

Page 48

background image

Part No. 4801-5338 Rev 01-10

Evolution 4000

48 of 86

Temp 1:

255

Outside:

255

Temp 2:

255

Humidity

1:

0

Temp 3:

255

Humidity

2:

0

Temp 4:

255

Feed 1:

0

Temp 5:

255

Feed 2:

0

Temp 6:

255

GP 1:

0

Temp 7:

255

Temp 8

255

Vent Opened:

No

Water 1:

Yes

Tunnel Closed:

No

Water 2:

Yes

Curt 1 Closed:

No

Run 1:

Off

Curt 2 Closed:

No

Run 2:

Off

Curt 3 Closed:

No

(12) Soft Resets - For HHI Use Only. Indicates that the control is sensing environmental problems which

can cause controller malfunctions.

(13) Voltage Resets - For HHI Use Only.
(14) Hard Resets -
For HHI Use Only.
(15) Analog and Digital Input Status – For HHI Service Technician Use ONLY.

A/D Readings:
These values will be used to troubleshoot your controller by a qualified service technician in the event that a
problem occurs with your PCB194 I/O board or connected analog and digital input devices.
The display view shown below is the bottom portion of the Program Setup > Diagnostics screen. These values
represent the information being received from various I/O connections.
Temp 1 through Temp 8 and the Outside Temp will display Analog-to-Digital values which represent the

temperature for the specific temperature sensor. The value may be from 0-256. Refer to the A-to-D /
Temperature chart provided in Section 10.

Humidity 1 and Humidity 2 will display Analog-to-Digital values which represent the humidity for the

specific Humidity Sensor. The value may be from 0 to 256 (0-100% Relative Humidity).

Feed 1 and Feed 2 will display Analog-to-Digital values which represent the current feed level for the specific

feed bin. The value may be from 0-256. Refer to the Feed Level Sensor Inputs chart below.

• The GP 1 analog input is a spare input which can be used for alternate analog devices. The value may be from

0-256.

• The Vent Opened, Tunnel Closed, Curt 1/2/3/4 Closed, Water 1&2, Run 1&2 are all digital inputs which

are toggled from either No to Yes or from Off to On by an open circuit or closed circuit (shorted condition to
ground). The conditions shown in the sample display window below are with open circuits or otherwise
unconnected terminal blocks. The terminal block Natural Auxiliary U1 Close (Curt 1) & U2 Close (Curt 2) are
quickly identified although Curt 3 and 4 connections are located at Vent Auxiliary Close (Curt 3) and Tunnel
Auxiliary Open (Curt 4).




























Feed 1 & Feed 2 - Feed Level Sensor Inputs

Range Status

Cause

0-24

Bin is full

Feed is on or above proximity rod.

25-57

Loss of
Echo

Bin may be empty or a sensor error

58-239

Sensing
Feed

Value should be based on level of
feed with 58 being approximately full.

240-255 Error

Could represent empty but probably a
defective sensor.

Feed 1 = Bin 1

Feed 2 = Bin 2

Temp 1 – Temp 8 &

Outside Temperature

Sensor Inputs

Run 1 & Run 2
Current Sensor Inputs

Water 1 & Water 2
Meter Inputs

PCB 194

Vent Inputs

Tunnel Inputs

Curtain/Natural
Inputs

GP 1 Input

Feed 1 & Feed 2

Inputs

Humidity 1 &

Humidity 2

Inputs