Part No. 4801-5338 Rev 01-10

Evolution 4000

32 of 86

**SENSOR SETUP**


(1)Room Temperature Sensors = --6-4-2-
(2)ALARM on Outside Sensor Error = Off

(3)SENSOR (4)ENABLED (5)VALUE (6)ADJUSTED
1 ON 77.0 + 3.0°
2 ON 77.0° + 1.0°
3 ON 77.0° +00.0°
4 OFF 77.0° +00.0°
5 OFF 77.0° +00.0°
6 OFF 77.0° +00.0°
7 OFF 77.0° +00.0°
8 OFF 77.0° +00.0°
OUT ---- 77.0° +00.0°

** Feed Level Module Setup **

(1)Bin 1:
(2)Diameter = 6 ft

(3)Cap Angle = 30°

(4)# of Rings = 1

(5)Ring Height = 2.67ft

(6)Feed wt: 00 lb (7)Bin ht: 9.07 ft

(8)Bin 2:
(9)Diameter = 6 ft (10)Cap Angle = 30°
(11)# of Rings = 1

(12)Ring Height = 2.67ft

(13)Feed wt: 00 lb (14)Bin ht: 9.07 ft

7.2 Network

Status

The Network Status shows the installed Evolution Stages and the Back-Up. The ENABLED indicator
shows if the stage is enabled and the STATUS indicates OK or Failed.
(1) Modules – The Evolution modules

that can be installed will appear
here. EV-INPUT/OUTPUT - This
is the PCB194 back board of the
Evolution 4000. EV-8 is the five
PCB191 boards on the lower portion
of the Evolution 4000 enclosure
door.


(2) Enabled – Those modules that are enabled will be indicated by Yes. This column lets you know which

modules are turned on for the Evolution control to communicate with. When adding expansion back-up
modules, the ENABLED must be set to “Yes” for proper operation.

(3) Status - OK or Failed. This column lets you know if you have lost communication with one of the

modules.

7.3 Temperature

Sensors

The Sensor Set-Up screen is used to set the temperature sensors that will be used to determine the internal
temperature of the building.

(1) Room Temperature Sensors -

Select any or all of the internal
sensors. Your alarm high and low
limits will use these sensors that are
displayed here.
For example: If you wanted to
display sensors 1,2,3,4,5 for your
room temperature it would look like
this: "---54321" If you turn all the
sensors off (by setting it to -) the
control would use the outside
temperature and it would look like
this: "Outside-".

(2) Alarm on Outside Sensor Error On or Off.
(3) Sensor – Identifies up to eight inside and one outside sensor.
(4) Enabled – Yes or No.
(5) Value – Current temperature reading.
(6) Adjusted – This will indicate if the sensor temperature has been calibrated and the amount of re-

calibration.

7.4

Feed Level Sensors

The Feed Level Module Setup screen sets
the parameters required to monitor feed
bins.
(1) Bin 1 - These settings provide the feed

level sensor at Bin #1 with necessary
information to calculate the
approximate feed weight and height.

(2) Diameter – Feed Bin #1 diameter =

6, 7, or 9 ft.

(3) Cap Angle – Feed Bin #1 cap angle at

the top of the bin = 30° or 40°

(4) # of Rings – Feed Bin #1 number of rings = 1, 2, 3, 4, or 5

(1)MODULES

(2)ENABLED (3)STATUS

EV-INPUT/OUTPUT Yes

OK

EV-8(1-8) Yes

OK

EV-8(9-16) Yes

OK

EV-8(17-24) Yes

OK

EV-8(25-32) Yes

OK

EV-8(33-40) Yes

OK

EV-16(41-56) No OK
BACK-UP/S3 Yes

OK