7 growout curve, 1 growout curve with optimum mode off – Hired-Hand Evolution 4000 Control System User Manual

Page 35

background image

Part No. 4801-5338 Rev 01-10

Evolution 4000

35 of 86

**TEMPERATURE RAMPING**

(1)Number of Points = 10 (2)Ramping = Off
(3)Preheat Target = 95.0° (4)Preheat = Off

(5)Target Temperature Differential

(6)POINT (7)DAY (8)TARGET
1

1

90.0°

2

5

88.0°

3

10

86.0°

4

15

84.0°

5

20

82.0°

6

25

80.0°

7

30

78.0°

8

35

76.0°

9

40

74.0°

10

45

72.0°

TARGET TEMPERATURE DIFFERENTIAL


(a)Enabled = Yes
(b)Target Adjust = +5.0°
(c)Adjust Between 11:00a and 1:00p

7.7 Growout

Curve

The Growout Curve is used to adjust the temperatures and/or minimum vent requirements automatically by
the grow-out day. The specific Growout Curve screen features and setting options will depend on whether
the Optimum Mode feature is turned ON or OFF. The Optimum Mode feature is selected by entering
“Program Setup” and then “General Settings”. Refer to Section 7.1.

7.7.1 Growout Curve With Optimum Mode OFF

(1) Number of Points –Select 2

through 10 points.

(2) Ramping – Select On or Off to

enable or disable ramping.

(3) Preheat Target – Target

Temperature for preheating.

(4) Preheat – On or Off. Preheat

allows the controller to run the
target to a higher set target
temperature for preheating the
house.






(5) Target Temperature Differential – When enabled, this feature will adjust the target temperature

either higher or lower by the selected number of degrees during the selected time of day.

a. Enabled – Select Yes

to enable or No to
disable Target
Temperature
Differential.

b. Target Adjust – The

desired degrees above
or below the Target
Temperature.

c. Adjust Between – The

selected time of day
for which the Target
Temperature
Differential will occur.