Installation – Lincoln Electric P709 GUARDIAN CONTROL SOLUTIONS User Manual
Page 9

A-2
INSTALLATION
GUARDIAN CONTROL™ SOLUTIONS
A-2
PHYSICAL DIMENSIONS AND PROPERTIES
TECHNICAL SPECIFICATIONS - OIL GUARDIAN™
FIRE PROTECTION
MATERIAL HOUSING
Steel
COLOR:
HOUSING
TOP COVER
Grey RAL 7011
Grey RAL 7035
WEIGHT (NET; WITHOUT LIMESTONE)
379 lbs. (172 kg)
CONTENTS LIMESTONE RESERVOIR
18.5 gallons / 70 liters (equal to 165 lbs / 75 kgs of
limestone
LIMESTONE ALARM LEVEL
<55 lbs. (25 kg); add 110 lbs. (50 kg)
LIMESTONE QUALITY
Calcium carbonate OmyaCarb
®
15 GU or equivalent
(not included; to be sourced locally)
LIMESTONE CONSUMPTION
MDB-4
MDB-24
10-20 g per filter cartridge per hour; e.g.:
40-80 g/h
240-480 g/h
PROTECTION CLASS CONTROL BOX
in accordance with:
IEC 60204
UL 508A
DISTANCE TO MAIN DUCT
Maximum 50 ft (15 m)
REQUIRED AIRFLOW IN DUCT
Minimum 25 ft/s (7.5 m/s)
ELECTRICAL DATA
CONNECTION VOLTAGE
400V/3ph/50Hz
480V/3ph/60Hz
600V/3ph/50Hz
MOTOR POWER:
UPPER (AGITATOR)
MIDDLE (AGITATOR)
LOWER (SCREW CONVEYOR)
250 W (0.33 HP)
375 W (0.5 HP)
90 W (0.1 HP)
AMBIENT CONDITIONS
OPERATING TEMPERATURE:
NORMAL
MINIMUM
MAXIMUM
41º (5ºC)
68º (20ºC)
113º (45ºC)
MAXIMUM RELATIVE HUMIDITY
80%
OUTDOOR USE ALLOWED
no
STORAGE CONDITIONS
41-113º F (5-45ºC)
Relative humidity maximum 80%
OPTIONS AND ACCESSORIES
EXTERNAL LIGHT POWER
For wall mounting