Maintenance, Spark guardian, Warning – Lincoln Electric P709 GUARDIAN CONTROL SOLUTIONS User Manual
Page 68: Attention, Safety, Periodic maintenance

D-5
MAINTENANCE
D-5
SPARK GUARDIAN™
SAFETY
• Observe the maintenance intervals given in this man-
ual. Overdue maintenance can lead to high costs for
repair and modifications and can render the guaran-
tee null and void.
• During service, maintenance and repair, always use
Personal Protective Equipment (PPE) to avoid injury.
This also applies to persons who enter the work area.
• Use appropriate climbing gear and safety guards
when working on a higher level than 6 feet (local
restrictions may apply).
PERIODIC MAINTENANCE
The Spark Guardian™ and the dustbin require period-
ic maintenance. You must learn from experience how
often this should take place, since the degree of pollu-
tion strongly depends on the welding process and the
intensity of use.
Cleaning of Spark Guardian™
The Spark Guardian™ can be cleaned in two ways:
1. A high-pressure cleaner with hot water
2. Industrial detergent type EFC
To clean the Spark Guardian™, proceed as follows.
1. Support the Spark Guardian™, preferably using a
hoist.
2. Demount the entire Spark Guardian™ by loosening
the duct clamps at both ends.
3. Disassemble the Spark Guardian™.
4. Clean the inlet and outlet of the housing (inside).
Let dry.
5. Assemble and mount the Spark Guardian™ in
reverse order.
Replacing The Dustbin
The dustbin cover is provided with a flexible hose to
facilitate replacement of the dustbin.
To replace the dustbin, proceed as follows.
Without manual damper:
1. Turn off the connected extraction fan.
2. Loosen the quick connect coupling (See Figure D.6,
Item C) and empty in accordance with federal, state
and local codes.
3. Close the dustbin using the lid supplied with the new
dustbin.
4. Install new dustbin and connect it in reverse order.
5. Turn on the extraction fan.
6. Dispose of the used dustbin in accordance with fed-
eral, state or local regulations.
GUARDIAN CONTROL™ SOLUTIONS
Always wear face mask respirator with HEPA fil-
ters, impermeable gloves and a disposable over
garment as a minimum during service, mainte-
nance and repairs.
-----------------------------------------------------------------------
WARNING
FIGURE D.5 – MAINTENANCE FREQUENCY
:
y
c
n
e
u
q
e
r
F
n
o
i
t
c
A
t
n
e
n
o
p
m
o
C
every # weeks
#=1
necessary; See Cleaning of
Spark Guardian™.
X
Dustbin
if necessary; See Replacing the
Dustbin.
X
Check pollution. Clean if
Spark Guardian™
#=2
Check level of contents. Replace
To avoid damage to the coating:
NEVER use acid base detergent.
------------------------------------------------------------------------
ATTENTION
FIGURE D.6
B
A
C