A-7

INSTALLATION

GUARDIAN CONTROL™ SOLUTIONS

A-7

PHYSICAL DIMENSIONS AND PROPERTIES

TECHNICAL SPECIFICATIONS - SLIDING VALVES

FIRE SUPPRESSION

MATERIAL HOUSING

Galvanized Steel

AMBIENT CONDITIONS

OPERATING TEMPERATURE:

MINIMUM

NOMINAL

MAXIMUM

-4ºF (-20ºC)

68ºF (+20ºC)

122ºF (+50ºC)

OUTDOOR USE ALLOWED

Yes (if housed in a weather-tight enclosure and com-

pressed air is not allowed to cool down below its dew

point)

SHIPPING DATA

GROSS WEIGHT

See Table A.1

PACKING DIMENSIONS

See Table A.1

HARMONIZED TARIFF CODE

8481.3091.90

COUNTRY OF ORIGIN

Germany

TECHNICAL DATA

PNEUMATIC CYLINDER

PRESSURE:

NORMAL

MAXIMUM

58-73 psi (4-5 bar)

131 psi (9 bar)

COMPRESSED AIR QUALITY

Dry and oil-free according to ISO 8573-3 class 6

SOLENOID VALVE

TYPE OF VALVE

5/2 solenoid valve with spring reset

ACTING TYPE

NC (normally closed)

POWER SUPPLY

24 VAC

POWER CONSUMPTION

3 W

ELECTRICAL CONNECTION

According to DIN 43650

POWER TOLERANCE

+/- 10%

POWER REQUIREMENT

Approx. 5 W

PROTECTION CLASS

IP 65

INSULATION CLASS

B

COMPRESSED AIR CONNECTION

Quick release for ø 0.24 in. (6 mm) hose