A-17

INSTALLATION

GUARDIAN CONTROL™ SOLUTIONS

A-17

3. Support the loose ends of the duct.

See Figure A.8.

4. Loosen all duct clamps(B).

5. Slide a duct clamp(B) Ø 250/400/500 mm over both

of the Spark Guardian(s)™(C).

• Duct metric size (mm):

Place a connection ring Ø 250/400/500 mm (A) in
both duct ends and fasten them using self-tapping
screws (min. 6).

• Duct imperial size (inch):

Place a reducer metric-imperial Ø 10/16/20 (A) in
both duct ends and fasten them using self-tapping
screws (min. 6).

6. Lift the Spark Guardian™ (C) in line with the duct

and mount it to the connection rings using the duct
clamps (B). Tighten the clamps using a box wrench.

DUSTBIN

The Spark Guardian™ comes with two different dust-
bins, which can be optionally mounted.

Recommended use:

• Spark Guardian™-250/400/10/16: dustbin 13 liters

• Spark Guardian™-400/500/16/20: dustbin 27 liters

The dustbin can be placed on the floor or on a frame
or small platform.

FIGURE A.7

D

A

B

B

C

C

E

A

mm

inch

A

min. 1000

min. 40

B

± 175

± 7

C

± 250

± 10

D

SparkShield-250
SparkShield-400
SparkShield-500

SparkShield-10
SparkShield-16
SparkShield-20

- 800
- 970
- 1180
- 915
- 1085
- 1295

- 31.5
- 38.2
- 46.5
- 36.0
- 42.7
- 51.0

E

± 150

± 6

INSPECTION
HATCH (TYP.-3)

Duct supports shall be designed to
support the weight of the Spark
Guardian™.

See Technical

Specifications for weight of Spark
Guardian™ in question.

-----------------------------------------------------------------------

WARNING

FIGURE A.8 – SPARK GUARDIAN™ MOUNTING

A

B

C

B

A

mm

mm

inch

inch