beautypg.com

Teledyne LeCroy Merlin Mobile - Users Manual User Manual

Page 82

background image

74

Merlin Mobile User’s Manual

CATC

SW Version 2.0

Show Paging Traffic

Show Paging Traffic causes Merlin Mobile to capture paging traffic
between the Master and Page Target devices. This option is used only with
Page Sync and Record Mode.

Correlation Value (33-64)

This value tells Merlin Mobile how many bits in the sync word of each
received packet must be matched in order for Merlin Mobile to consider the
packet valid and start recording.

It is recommended that the Correlation Value be set to 57 bits.

Inquiry Timeout (0-80 secs)

Default value is 20 seconds.

This value specifies how long Merlin Mobile should perform the Inquiry
process for the General (unlimited) and Dedicated (limited) recording
modes. After the specified time has elapsed, Merlin Mobile will illuminate
the trigger light on the front of the analyzer.

Loss of Sync Timeout (1-30 secs)

This value specifies the amount of time that Merlin Mobile will wait for
piconet traffic before determining that synchronization has been lost.

Sync Window

The Sync Window slide bar controls the amount
of time that Merlin Mobile should wait between
receiving an Inquiry Response (which will cause
the Sync LED to blink) and detecting Master-Slave piconet traffic (which
will cause the Sync LED to turn solid.)

A "Narrow" setting means that the wait time will be minimal, a "Wide"
setting means it will be "maximal." The default is "Narrow" and this is
suitable for most recordings. However, if significant drift occurs between
Merlin Mobile’s clock and that of the Master, Merlin Mobile may not be
able to sync properly to the piconet. Under these conditions, you should
move the slide bar towards the "Wide" Setting. The slide bar has five
discrete settings.

After sync is established, Merlin Mobile will remain in sync as long as there
is piconet traffic.