beautypg.com

Trigger position, 4 recording options - piconet, Recording options - piconet – Teledyne LeCroy Merlin Mobile - Users Manual User Manual

Page 75

background image

67

Merlin Mobile User’s Manual

CATC

SW Version 2.0

The Recording Type option determines how this buffer is used. Although
there are 512 megabytes of physical memory in the analyzer, the efficiency
of the recording ranges from 2:1 to 4:1 ratios of physical memory to actual
Bluetooth traffic. Shorter Bluetooth packets yield a less efficient recording.
The non-traffic portion of physical memory is utilized for control and timing
information.

Note

The scale is not linear and affords more granularity in the smaller buffer sizes.

Trigger Position

The Trigger Position slide bar sets the amount of
post-trigger recording that Merlin Mobile will
perform. It also allows adjustment of the location of
the trigger within the defined buffer. You can adjust
the Triggering Position between 1 and 99%
post-Trigger. Trigger Position is available only when Manual Trigger or
Event Trigger is selected as Recording type.

As an example, if the buffer size is set to 16MB, then for the following
Trigger Position settings, the amount of pre- and post-Trigger data is

95% post-triggering: 0.8MB pre-trigger, 15.2MB post-trigger

75% post-triggering: 4MB pre-trigger, 12MB post-trigger

50% post-triggering: 8MB pre-trigger, 8MB post-trigger

25% post-triggering: 12MB pre-trigger, 4MB post-trigger

5% post-triggering: 15.2MB pre-trigger, 0.8MB post-trigger

Note

When a Trigger occurs, recording continues until the post-Trigger amount of the
buffer is filled.

6.4 Recording Options - Piconet

The Recording Options dialog box has two pages for configuring how
Merlin Mobile records Bluetooth traffic: Piconet, which configures piconet
recording sessions, and Inquiry which configures inquiry recording
sessions.