8. Installation

43

[Mounting procedure]

1) Check the accuracy on the actuator side and load side.

Adjust the position so the accuracy can be maintained at the value shown below or less in the

whole range of the load side movement.

L

A

A

0.02

0.05 B

B

Load-side bracket

Actuator-mounted-side bracket

2) Mount the main unit of the actuator.

3) Move the load-side bracket to confirm that there is no problem in the precision of the position to

the shaft of the rod.

Confirm that the shaft of the rod can be inserted without a touch to the inside face of the mating

hole on the bracket.

Confirm a smooth insertion

without interference or touch

Caution : Make sure to have the position accuracy for the actuator and the load side as

indicated.

Failure to do so may cause abnormal noise, vibration, operational failure or shorter

product life.