Specifications, Model x96s – Ronan X96S DENSITY GAGE User Manual
Page 65
Density Gage Manual 012407
61
SPECIFICATIONS
MODEL X96S
Process Computer:
Microprocessor-based unit wit a liquid crystal display, push-button interface,
HART
®
Communications, process control outpus, process condition inputs, serial
communications.
Chassis:
19” Rack Mount, Surface Mount or Panel Mount
Enclosure:
Standard NEMA-4
Stainless Steel NEMA-4X
Explosion Proof
Electrical:
Power inputs: 90 to 24 VAC +/- 15%, 50/60 Hz; 24 VDC +/- 15%
Environmental:
Ambient Temperature Range: 0° to 140° F° (-18° to 60° C)
Hunidity: 90% Non-Condensing
Electronics:
Processor: Embedded 80 x 86 Compatible Processor
Memory: Flash, Static RAM, battery Backup RAM
A/D Converters: 16-bit, Dual Slope, Auto-Zeroing
Display: Graphic LCD, Fluorescent Back-lit
Inputs:
(Optional)
Tachometer: 0-10 VDC, 4-20 mA, or Pulse Rate TTL Load
Detector: 0.42-2.4 VDC or Pulse TTL
Temperature Compensation: 100 Ohm Pt, 120 Ohm Ni, or 4-20 mA
(Mass Flow or Density)
Outputs:
(Optional)
Three 4-20 mA; One assigned to each Channel
Four Single Set-point SPDT Relays: 3 Amp at 28 VDC or 240 VAC
Remote Totalizer Pulse: 20 msec Pulse, Open Collector 50 mA at 24 VDC
Display Units:
(Engineering Units per Gage)
Level: in, ft, mm, cm, or m
Density: % Solids; SpG, Baume H, Baume L, API, Brix, Ball, or Twaddell
Mass Flow: lb/mn, kg/min, mT/min, mT/hr, sT/min, sT/hr, IT/min or IT/hr
Weight: lb/min, kg/min, mT/hr, sT/hr, IT/hr, kg/hr or oz/min
Computer Interface:
HART
®
and Communications