Hardware menu – Ronan X96S DENSITY GAGE User Manual
Page 25
Density Gage Manual 012407
21
Hardware Menu
The Hardware menu is used to define the type of hardware used to provide measurements and radiation. It contains the
following items:
ITEM
FUNCTION
System Hardware
Shows the user the list of hardware modules in the system and the status of these
modules
Proc Temp
Shows and allows the user to set the type of device used to read process temperature
Source Type
Selecting this item takes the user to the Source Type menu
Pressure
Shows and allows the user to set the type of device used to read process pressure
Analog Out Config
Shows and allows the user to set the source of power as internal or external
HART Output
Shows and allows the user to adjust the HART output functions
Com1 Protocol
Shows and allows the user to adjust the Com1 Protocols [None/Hart/Ronan Setup]
The System Hardware menu takes the user to a list of the hardware modules in the system and the status of these modules:
ITEM
FUNCTION
CPU Card
Shows the type of CPU card installed (in slot 1)
CPU Status
Status of the CPU card
DIO Card
Shows the type of DIO (Digital Input/Output) card installed (in slot 2)
DIO Status
Status of the DIO card
Slot 3 Card
Shows the type of card (if any) installed in slot 3
Slot 3 Status
If a card is installed in slot 3, shows the status of the card, else shows None
Slot 4 Card
Shows the type of card (if any) installed in slot 4
Slot 4 Status
If a card is installed in slot 4, shows the status of the card, else shows None
Slot 5 Card
Shows the type of card (if any) installed in slot 5
Slot 5 Status
If a card is installed in slot 5, shows the status of the card, else shows None
Slot 6 Card
Shows the type of card (if any) installed in slot 6
Slot 6 Status
If a card is installed in slot 6, shows the status of the card, else shows None
Slot 7 Card
Shows the type of card (if any) installed in slot 7
Slot 7 Status
If a card is installed in slot 7, shows the status of the card, else shows None
Slot 8 Card
Shows the type of card (if any) installed in slot 8
Slot 8 Status
If a card is installed in slot 8, shows the status of the card, else shows None
Display X96-2002
Shows the type of display module (if any attached)
Display Status
Shows the status of the display module if attached, or else shows None
HART X96-2005
Shows the type of the HART interface (if any) present
HART Status
Shows the status of the HART interface, if the interface is present, else shows None
Proc Temp is one of the following:
ITEM
MEANING
None
No temperature measurement device configured
pt100_a_385
Platinum RTD with an alpha of 885 (commonly used in USA)
pt100_a_392
Platinum RTD with an alpha of 892 (commonly used in Europe)
ni120
Nickel RTD
0-10 volts
Temperature measurement device that provides a 0 to 10 volt signal
4-20 ma
Temperature measurement device that provides a 4-20 ma signal