Section 3: Access Terminal Screens Defined
01/13
94
51299 Rev. 1
3.3.5. Rfid Reader Setup, Continued
RFID Model: Pongee Pegasus Readers
Pongee Pegasus Readers: The Pegasus reader sends card numbers continuously
and there are often a number of erroneous readings. The following settings will allow
the terminal to filter out the actual card number that is being detected
Required Readings: Make the reader send a number of readings before looking for
a card number. This should be in the range of 6-9.
Readings Per ID: Set the number of readings of an ID that must be with in the
required number of readings before that ID would be considered valid. For example,
if the previous setting is 6 and this setting is 3, then there will be a total of 6 readings.
For an ID to be considered value, there must be 3 readings of that ID out of the 6
readings available.
Reading Window: Since the readings are continuously coming in a reading window
is required. This prevent a duplicate erroneous reading from being considered a card
when the readings come in every so often. The default value is 30 seconds.